ELECTRICAL REQUIREMENTS
CAUTION:  The dispenser must remain disconnected from power source until specified in Electrical Hook-Up.
 
The LCR-2 dispenser is supplied with a 120-volt / 15 Amp cord set and require a 2-wire, grounded, individual branch 
circuit rated for 120 volts AC, 15 amp, single phase, 60Hz.  The mating connector must be a NEMA 5-15R.
 
The LCR-2C dispenser is supplied with a 120-volt / 20 Amp cord set and require a 2-wire, grounded, individual branch 
circuit rated for 120 volts AC, 20 amp, single phase, 60Hz.  The mating connector must be a NEMA 5-20R.
 
These dispensers can be Field Wired for 208 or 240 volt applications. This requires a 2 or 3-wire, grounded, individual 
branch circuit rated for 208/240 volts AC, 30 amp, single phase, 60 Hz. 
NOTE:   The internal terminal block must be rewired for 208/240 applications, (see Optional Field Wiring Diagram).
120V A.C.
120V A.C.
208 or
240V A.C.
HEATER RED
208 or
240V A.C.
120V A.C.
10A. FUSE - WHITE
HEATER RED
10A. FUSE - WHITE
10A. FUSE - BLACK
LIMIT SW. - BLACK
HEATER RED
10A. FUSE - WHITE
10A. FUSE - BLACK
LIMIT SW. - BLACK
10A. FUSE - BLACK
LIMIT SW. - BLACK
FIELD WIRING TERMINAL BLOCK DIAGRAM
For all 208 - 240 Volt Connections: Use No. 10 AWG Wires suitable for 90°C (194 °F)
1. Unit shipped per Fig. 1, wired for 120V A.C./2-Wire.
2. For 208 - 240V A.C./2-Wire per Fig. 2: Move both the Red-Heater wire and the White-Fuse wire to the Top Red Terminal as shown.
3. For 120/208 - 240V A.C./3-Wire per Fig. 3: Move the Red Heater wire to the Top Red Terminal as shown.
Fig. 1
Fig. 2
Fig. 3
Optional Field Wiring
208-240 V, 25.8 A, 6200 W
1PH, 2-Wire + GND, 60HZ
or
120/208-240 V, 25.8 A, 6200 W
1PH, 3-Wire + GND, 60HZ
28181.0003
USER NOTICES (Cont)
Optional Field Wiring
230 V,  26 A,  6000 W
1PH,  2-Wire + GND,  50/60HZ
or
230 V, 13 A, 3000W
1PH, 2-Wire + GND, 50/60HZ
29710.0014
39762.0000
36026 031307
120V A.C.
120V A.C.
208 or
240V A.C.
RED
208 or
240V A.C.
120V A.C.
TO MASTER
ON/OFF
SWITCH
BLACK
RED
TO MASTER
ON/OFF
SWITCH
BLACK
RED
TO MASTER
ON/OFF
SWITCH
BLACK
FIELD WIRING TERMINAL BLOCK DIAGRAM
For all 208 - 240 Volt Connections: Use No. 10 AWG Wires suitable for 90°C (194°F)
1. Unit shipped per Fig. 1, wired for 120V A.C./2-Wire.
2. For 208 - 240V A.C./2-Wire per Fig. 2. 
3. For 120/208 - 240V A.C./3-Wire per Fig. 3.
Fig. 1
Fig. 2
Fig. 3
FIELD WIRING TERMINAL BLOCK DIAGRAM
Models with Master ON/OFF Switch
FIELD WIRING TERMINAL BLOCK DIAGRAM
Models without Master ON/OFF Switch