SERVICE (cont.)
SOLENOID VALVE
FIG. 28 SOLENOID VALVE
Location:
The solenoid valve is located inside the hood on
the right side of the upper component bracket.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Remove both wires from the solenoid valve coil
terminals.
3. With  a  voltmeter,  check  the  voltage  across  the
removed wires:
a.) White and violet wires on 120, 120/208 and
120/240 volt brewers.
b.) Red and violet wires on 200, 230 or 240 volt
brewers.
Connect  the  brewer  to  the  power  source.  The
indication must be:
c.) 120 volts ac for two wire 120 volt models, three
wire 120/208 volt models and three wire 120/240
volt models.
d.) 200 to 240 volts ac for two wire 200, 240 or 240
volt models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If  voltage  is  not  present  as  described,  refer  to  the
Wiring  Diagrams  and  check  brewer  wiring  harness
terminals.
5. Check for continuity across the solenoid valve coil
terminals.
FIG. 29 SOLENOID VALVE TERMINALS
P835
P2230
22978.0000
TL5
TL4
TL3
TL2
TL1
J2
J1
SE
T   
  LO
CK
LOCK
SET
     1    2    3    4    5     6
a
ting pressure
#
 22300.033  0
2
0526.0330)
1
.0000)
5
00 gpm FLOW
VIO to Level Control Board T1 
WHI to Level Control Board T3
(120V,120/208V,120/240V Models)
Red to Level Control Board T3 (200 or 240V
Models)
28230 092200
If  continuity  is  present  as  described,  reconnect  the
white and violet wires on 120, 120/208 and 120/240
volt brewers,  red and violet wires on 200, 230 or 240
volt brewers.
If continuity is not present as described, replace the
solenoid valve.
6. Check the solenoid valve for coil action. Connect
the brewer to the power source. Listen carefully in
the vicinity of the solenoid valve for a "clicking"
sound after approximately 1 second, as the coil
magnet attracts.
7. Disconnect the brewer from the power source.
If the sound is heard as described and water will not
pass  through  the  solenoid  valve,  there  may  be  a
blockage in the water line before or after the solenoid
valve,  or  the solenoid valve may require inspection for
wear and removal of waterborne particles.
If  the  sound  is  not  heard  as  described,  replace  the
solenoid valve.
Removal and Replacement:
1. Remove all wires from the solenoid valve coil.
2. Turn off the water supply to the brewer.
3. Disconnect the water lines to and from the sole-
noid valve.
4. Remove the two #10-32 slotted head screws and
lockwashers  holding  the  solenoid  valve  to  the
upper component bracket.
5. Lift out the solenoid valve.
6. Securely  install  the  new  solenoid  valve  to  the
upper component bracket.
7. Securely  fasten  the  water  lines  to  and  from  the
solenoid valve.
8. Refer to Fig. 29 when reconnecting the wires.