TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems 
encountered.  If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic 
Technical Service Department.
 
• 
Inspection, testing, and repair of electrical equipment should be performed only by qualified 
service personnel.
 
• 
All electronic components have 120 - 240 volt ac and low voltage dc potential on their terminals.  
Shorting of terminals or the application of external voltages may result in board failure.
 
• 
Intermittent operation of electronic circuit boards is unlikely.  Board failure will normally be per-
manent.  If an intermittent condition is encountered, the cause will likely be a switch contact or 
a loose connection at a terminal or crimp.
 
• 
Solenoid removal requires interrupting the water supply to the valve. Damage may result if sole-
noids are energized for more than ten minutes without a supply of water.
 
• 
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. 
This will help avoid twists and kinks in the tubing.
 
• 
Make certain that all plumbing connections are sealed and electrical connections tight and iso-
lated.
 
• 
This brewer is heated at all times. Keep away from combustibles. 
WARNING
  
 
• Exercise extreme caution when servicing electrical equipment.
  
 
• Disconnect the brewer from the power source when servicing, except when electrical tests  
  
 
are specified.
  
 
• Follow recommended service procedures.
  
 
• Replace all protective shields or safety notices.
Screen Displayed 
 
 
Possible Cause
Troubleshooting Procedure
1. Overflow cup is full of water. This 
could be caused by boiling; see chart 
on page 29. Also could be Refill Sen-
sitivity adjustment; see page 30.
1.  Soft  Heat  Server  not  correctly 
positioned on base.
2. Not using a Soft Heat Server, and 
the  SERVER  DETECT  function  is 
activated (on).
Empty  cup.  Correct  cause  and 
retry.
Position the server so that the con-
nector pins on the server make con-
tact with connector on the brewer.
Disable the SERVER DETECT func-
tion.
OVERFLOW CUP
FULL. EMPTY CUP
SERVER NOT
IN PLACE