Bunn single tf brewwise dbc Guía De Operación

Descargar
Página de 54
Page 38
to TEST SWITCHES.
7.  Pressing  NO  in  this  screen  will  advance  to  the  
next function. Press YES in the TEST SWITCHES 
screen to test the switches. The display will read 
NOTHING PRESSED.
8.  From this screen, press any of the switches on the 
front of the brewer. While the switch is pressed, 
the display shows the name of that switch. If the 
name does not appear, or if it remains after the 
switch has been released, the switch is defective.  
Each switch can be tested in this manner. 
9.  After all switches have been tested, press the up-
per right hidden switch located on the front switch 
panel. This will exit TEST SWITCHES and return 
to the MAIN SCREEN.
Procedures to test coil frequency:
1.  Place brew funnel into rails of the brewer.
2.  Place a server beneath the brew funnel.
3.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads 
SERVICE TOOLS.
4.  Pressing NO  will exit this function and advance to 
the next function screen. Press YES to run tests 
on  various  components  and  outputs  within  the 
brewer.
5.  The display should read TEST OUTPUTS.
6.  In TEST OUTPUTS screen, press NO. Continue to 
press and release NO until the display reads  TEST 
FREQUENCY.
7.  Press and release YES. The display will show the 
frequency of the sensor coil circuits. This is for 
diagnostic service use when troubleshooting this 
circuit.
8.  After the coils have been tested, press and release 
the ON/OFF switch located on the front switch panel. 
This will exit the TEST FREQUENCY function and 
return to the MAIN SCREEN.
NOTE: If the operator wishes to test more than one 
function in the SERVICE TOOLS section (outputs, 
switches,  servers,  or  coil  frequency),  it  is  not 
necessary to exit the program. Use the flow chart 
for  SERVICE  TOOLS  to  navigate  to  a  particular 
function.
SERVICE TOOLS (cont.)
14. Press OFF to retract the funnel lock.
15. Press NEXT to advance to the next component to 
be tested.
16. To test REFILL VALVE, press ON. If the refill valve 
is functional, the sound of the valve operating will 
be heard.
17. Press OFF to end testing of refill valve.
18. Press NEXT to advance to the next component to 
be tested.
19. To test TANK HEATER, connect a voltmeter across 
the tank heater to check for voltage.
20. Press ON. The correct voltage should be present 
at the heater terminals.
21. Press OFF to end testing of the tank heater.
NOTE: The tank heater will automatically turn off if 
left on too long.
22. After testing the tank heater, press NEXT to advance 
to the next test.
23. The HEATER CONTACTOR is used only on certain 
models. Check the machine schematic to see if the 
contactor is present. Connect a voltmeter across 
the tank heater and press ON to check that cor-
rect voltage is present. Press OFF and confirm the 
voltage is zero.
24. Press NEXT to return to TEST OUTPUTS.
25. To exit SERVICE TOOLS, press and release the 
ON/OFF switch located on the front switch panel. 
This will return to the MAIN SCREEN.
Procedure to test switches:
 
This function allows the operator to test the opera-
tion of the individual switches on the front panel.
1.  Place brew funnel into rails on the brewer.
2.  Place a server beneath the brew funnel.
3.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads 
SERVICE TOOLS.
4.  Press YES to run tests on various components 
and outputs within the brewer. (Pressing NO will 
exit this function and advance to the next function 
screen.)
5.  The display should read TEST OUTPUTS.
6.  In TEST OUTPUTS screen, press NO.  This advances 
PROGRAMMING THE BREWER (cont.)
35879.1 071405