LIMIT THERMOSTAT
SERVICE (cont.)
J2
SET
     L
OC
K
LO
C
K
SE
T
TL
1
TL
2
TL
3
TL
4
TL
5
J1
P1800
FIG. 11 LIMIT THERMOSTAT TERMINALS
FIG. 10 LIMIT THERMOSTAT
P09.60
Location:
 
The limit thermostat is located on the center front 
of the component bracket behind the timer mounting 
bracket.
Test Procedures:
1.  Disconnect the brewer from the power source.
.  Disconnect the black wires or the red wires from 
the limit thermostat.
3.  With an ohmmeter, check for continuity across 
the limit thermostat terminals.
If continuity is present as described, the limit thermostat 
is operating properly.
If continuity is not present as described, replace the 
limit thermostat.
BLK to Control 
Thermostat(All 
Models Except 
30V CE Models)
RED to Control 
Thermostat 
(30V Models)
Removal and Replacement:
1.  Remove the wires from the limit thermostat ter-
minals.
.  Carefully slide the limit thermostat out from under 
the  retaining  clip  and  remove  the  limit  thermo-
stat.
3.  Carefully slide the new limit thermostat into the 
retaining clip.
4.  Refer to Fig. 11 and reconnect the wires.
10060  080900
BLK to Contactor 
(All Models Except 
30V CE Models)
Red to Contactor 
(30V CE Models)