Page 9
START SWITCH (BREW)
FIG. 4 START SWITCH (BREW)
P1317.30
Location:
 
The brew start switch is located on the upper right 
side of the brewer component housing.
Test Procedures:
1.  Disconnect the brewer from the power source.
.  Remove  the  wires  from  the  start  switch  termi-
nals.
3.  Check for continuity across the switch terminals 
when  the  switch  is  held  in  the  lower  position. 
Continuity must not be present when the switch 
is in the upper position.
If continuity is present as described, reconnect the 
wires the switch is operating properly.
If continuity is not present as described, replace the 
switch.
BLU to Brew Timer or 
Brew Lockout Relay
BLK from ON/OFF Switch
ALL MODELS EXCEPT 30V - CE MODELS
BLU to Brew Timer or
Brew Lockout Relay
RED from ON/OFF
Switch
30V - CE MODELS
FIG.5 BREW START SWITCH TERMINALS
P1743
SERVICE (cont.)
Removal and Replacement:
1.  Remove the wires from the switch terminals.
.  Compress the clips on the back side of the switch 
mounting bracket and gently push the through the 
opening.
3.  Push the new switch into the opening and spread 
the clips to hold switch in the mounting bracket.
4.  Refer to Fig. 5 and reconnect the wires.
10060  031599