Bunn U3 Manuales De Servicio

Descargar
Página de 41
Page 35
BLK from 
Terminal Block
SERVICE (cont.)
TRANSFORMER (380V THREE WIRE MODELS ONLY)
J2
SET
     L
OC
K
LO
CK
SE
T
TL
1
TL
2
TL
3
TL
4
TL
5
J1
FIG. 34 TRANSFORMER
P175
Location:
 
The transformer is located on the top rear of the 
timer mounting bracket.
Test Procedures:
1.  Disconnect the brewer from the power source.
.  Disconnect black wire and the red wire from the 
terminal block at the transformer.
3.  With  a  voltmeter,  check  the  voltage  across  the 
black wire and the red wire. Connect the brewer 
to the power source. The indication must be 380 
volts ac.
4.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to wiring 
diagram and check the brewer wiring harness.
5.  Reconnect the black wire and the red to the trans-
former.
6.  Disconnect the black wire and the white wire from 
the transformer terminals.
7.  With  a  voltmeter,  check  the  voltage  across  the 
transformer terminals. Connect the brewer to the 
power source. The indication must be 10 volts 
ac.
If voltage is present as described, the transformer is 
operating properly
If  voiltage  is  not  present  as  described,  replace  the 
transformer.
Removal and Replacement:
1.   Disconnect all the wires from the transformer.
.  Remove the two #8-3 screws securing the trans-
form to the transformer mounting bracket.
3.  Remove the transformer and discard.
4.  Position new transformer on transformer mounting 
bracket and secure with two #8-3 screws.
5.   Refer to Fig. 35 and reconnect the wires.
RED from 
Terminal Block
WHI from Main 
Harness
BLK from 
Main Harness
FIG. 35 TRANSFORMER TERMINALS
P1753
10060  031599