Avaya P550 Guía De Referencia
===NJPQ
`Ü~éíÉê=N
`~àìå=mRRMLmUUM=pïáíÅÜ=^qj=`if=réäáåâ=oÉÑÉêÉåÅÉ=dìáÇÉI=sÉêëáçå=NKN
ëÉí=äÉÅ=Eã~ñJíáãÉF
`çãã~åÇ=jçÇÉ
Configuration
aÉëÅêáéíáçå
Set the unknown frame time interval for a LEC.
* Note: You must disable a LEC each time you make a change to
the configuration. After you make configuration
changes, you must enable the LEC in order for the
changes to take effect.
changes, you must enable the LEC in order for the
changes to take effect.
póåí~ñ
set lec <lecID> max-time <max-time-value>
q~ÄäÉ=NJOSK==m~ê~ãÉíÉêëI=hÉóïçêÇëI=^êÖìãÉåíë
p~ãéäÉ=lìíéìí
This example sets the unknown frame time interval for LEC 2 to 45
seconds.
seconds.
ATM(configure)# set lec 2 disable
LEC 2 has been disabled
ATM(configure)# set lec 2 max-time 45
Maximum Unknown Frame Time 45 has been set for
LEC 2
ATM(configure)# set lec 2 enable
LEC 2 has been enabled
Name
Definition
lecID
The LEC identifier. The range of values is:
Minimum = 1, Maximum = 128.
Minimum = 1, Maximum = 128.
max-time-value
The maximum unknown frame time,
measured in seconds. The range of values is:
Minimum = 1 second, Maximum = 60 seconds.
The default is 1.
measured in seconds. The range of values is:
Minimum = 1 second, Maximum = 60 seconds.
The default is 1.