Gateway fx6800 Guía De Referencia

Descargar
Página de 154
www.gateway.com
35
Drawback
RAID 1 treats the entire array as a single drive with the storage 
capacity of the smallest physical drive in the array. So if you 
have two drives (300 GB and 250 GB) in a RAID 1 array, your 
computer only recognizes a single drive with 250 GB total 
capacity.
RAID for both: performance and security
RAID 5 uses striping (at the block level) with on-the-fly error 
correction across all drives. Because of this error correction, 
small file read/write errors can be quickly and automatically 
fixed without a significant drop in system performance. 
RAID 5 offers good performance and data redundancy. This 
array preserves your files if a drive fails.
RAID 5 stripes both data and parity information across 
multiple drives. Striping across drives improves overall 
performance, and the parity information provides data 
protection. Because of the error-correction capabilities, if a 
drive fails, the data can be quickly and automatically fixed.
RAID 10 (also called RAID 1+0 or RAID 1&0) contains sets of 
RAID 1 mirrors acting as drives within a RAID 0 striping array. 
With this setup, the array could survive one drive failure in 
each mirror array.
A1
B1
CP
A2
BP
C1
AP
B2
C2
RAID 5
A
C
E
A
C
E
B
D
F
B
D
F
RAID 0
RAID 1
RAID 1
8511858.book  Page 35  Monday, December 18, 2006  10:51 AM