Sony fwd-50px3 Manual

Descargar
Página de 28
21
FWD-50PX3
(e) 8bits Register
Syntax
Header
Category
Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
Code Table (4-b)
0xFF
0xFF
0xXX
Answer
Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x70
0x00
0x02
Code Table (4-b)
0xXX
Completed
Code Table (4-b)
*
Function
Return Data
Unit
0x07
Digital 3.3 V
0x00-0xFF
0x08
Main Power (Vs)
0x00-0xFF
0x09
Digital 5 V
0x00-0xFF
0x0A
Temp1
0x00-0xFF
0x0B
Temp2
0x00-0xFF
0x0C
Temp3
0x00-0xFF
0x10
Analog 9 V
0x00-0xFF
0x11
Shutdown Log
0x00-0xFF
0x12
Digital 3.3 V (Failure)
0x00-0xFF
0x13
Digital 5 V (Failure)
0x00-0xFF
0x14
Analog 9 V (Failure)
0x00-0xFF
0x15
Main Power (Va)
0x00-0xFF
0x16
Analog Power 12 V
0x00-0xFF
(f) Shutdown Log
Syntax
Header
Category
Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0x11
0xFF
0xFF
0xC2
Answer
Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x70
0x00
0x02
Shutdown Log
0xXX
Completed
Code Table (4-c)
Return Data1: 0x00-0xFF
Code Table (4-c)
Shutdown Information
bit0
Reserved
bit1
1: FAN Sensor Abnormal
0: Normal
bit2
1: Panel Voltage Abnormal
0: Normal
bit3
1: Temperature Sensor Abnormal
0: Normal
bit4
Reserved
bit5
1: Power Abnormal (3.3 V, 5 V)
0: Normal
bit6
1: Analog Power Abnormal (12 V, 9 V, 5 V)
0: Normal
bit7
Reserved
* FWD-50PX3 returns not the AD value but the
display value.
..... For function 0x08 and 0x15
When the display value is 190 V, 0xBE (190) is
returned.
..... For function 0x0A, 0x0B and 0x0C
When the display value is 50 deg, 0x32 (50) is
returned.
When the display value is -20 deg, 0xEC is
returned.
..... For function 0x07, 0x09, 0x10, 0x12, 0x13, 0x14
and 0x16
When the display value is 3.0 V, 0x1E (30) is
returned.