Before calling for service, review this list, it may save you time and expense. This list includes common 
occurrences that are not the result of defective workman-ship or materials in this appliance. 
Air conditioner 
does not start 
 
Air from unit 
does not feel 
cold enough 
 
Air conditioner 
cooling, but room is 
too warm. Ice 
forming on cooling 
coil behind 
decorative front 
 
Air conditioner 
cooling, but room is 
too warm. NO Ice 
forming on cooling 
coil behind 
decorative front 
 
Air conditioner turns 
on and off rapidly 
 
Noise when unit is 
cooling
 
Water dripping INSIDE 
when unit is cooling
 
 
Wall plug disconnected. Push plug firmly into wall outlet. 
 
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or 
reset circuit breaker. 
 
Plug Current Device tripped, press the RESET button. 
 
Control is OFF, turn control ON and set to desired setting. 
 
Room temperature below 17°C (62°F). Cooling may not  occur until room 
temperature rises above 17°C (62°F). 
 
Temperature sensing element is touching the cooling coil, located behind air filter. 
Gently bend the element away from cooling coil. 
 
Set temperature has been reached. Lower set temperature. 
 
Compressor shut-off due to mode change. Wait approximately 3 minutes and listen 
for compressor to restart in COOL mode. 
 
Outdoor temperature below 18°C (64°F). To defrost t he coil, set FAN only mode. 
 
Air filter may be dirty, clean filter. Refer to Care and Cleaning section. 
 
Thermostat set too cold for nighttime cooling, set a higher temperature. 
 
To defrost the coil, set to FAN only mode.  
 
Air filter is dirty and restricting air flow. Clean air filter. 
 
Temperature is set too high, set to a lower temperature setting. 
 
Air directional louvers positioned improperly. Position louvers for better air distribution. 
 
Front of unit is blocked and airflow restricted. Clear blockage such as drapes, blinds, 
furniture, etc. 
 
Doors/windows are open, allowing cold air to escape. Close doors/windows. 
 
Unit recently turned on in hot room, allow additional time to remove “stored heat” from 
walls, ceiling, floor and furniture. 
 
Dirty air filter restricting airflow. Clean air filter 
 
Outside temperature extremely hot. Set FAN speed to a higher setting to bring air past 
cooling coils more frequently. 
 
Air movement sound. This is normal. If too loud, set to a slower FAN setting. 
 
Window vibration – poor installation. Refer to installation guide or check with installer. 
 
Improper installation. Tilt air conditioner slightly toward the outside to allow water 
drainage. Refer to installation instructions or check with installer.