LG 42LY540S Manual De Propietario

Descargar
Página de 67
61
ENG
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
Communication Parameters
 
y
Baud rate: 9600 bps (UART)
 
y
Data length: 8 bits
 
y
Parity : None
 
y
Stop bit: 1 bit
 
y
Communication code: ASCII code
 
y
Use a crossed (reverse) cable.
Command Reference List
(Depending on Model)
COM-
MAND1
COM-
MAND2
DATA
(Hexa-
decimal)
COM-
MAND1
COM-
MAND2
DATA
(Hexa-
decimal)
01. Power
k
a
00 to 01
12. Remote 
Control
Lock Mode
k
m
00 to 01
02. Aspect Ratio
k
c
(
)
13. Balance
k
t
00 to 64
03. Screen Mute
k
d
(
)
14. Colour 
Temperature
x
u
00 to 64
04. Volume Mute
k
e
00 to 01
15. Energy 
Saving
j
q
00 to 05
05. Volume 
Control
k
f
00 to 64
16. Auto Con-
figuration
j
u
01
06. Contrast
k
g
00 to 64
17. Equalize
j
v
07. Brightness
k
h
00 to 64
18. Tune Com-
mand
m
a
08. Colour
k
i
00 to 64
19. Programme 
Add/Skip
m
b
00 to 01
09. Tint
k
j
00 to 64
20. Key
m
c
10. Sharpness
k
k
00 to 32
21. Control 
Back Light
m
g
00 to 64
11. OSD Select
k
l
00 to 01
22. Input select 
(Main)
x
b
 NOTE
 
y
During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are 