Ordering inFOrmatiOn
Page 2
800-675-8410 • 949-250-6510  •  www.omnitron-systems.com  •  info@omnitron-systems.com  •  140 Technology Dr., Irvine, CA 92618
iConverter 
5-Module Chassis
© 2011 Omnitron Systems Technology, Inc.  All rights reserved.  iConverter and NetOutlook are Registered Trademarks of Omnitron Systems Technology, Inc.  
Trademarks are owned by their respective companies.  Specifications are subject to change without notice.  
091-18220-001F 
7/11
speciFicatiOns
management
Management is accomplished by using an optional iConverter  
Network  Management  Module  (NMM2),  which  is  capable 
of  managing  up  to  19  iConverter chassis  using  a  single  IP 
address.  Management can also be accomplished by using 
an iConverter module with integrated management, such as 
the 10/100M2 managed media converter.  Management can 
be accessed through a menu-driven command-line interface 
(CLI) via Telnet or the Serial Console Port, or can be accessed 
through a SNMP-based graphical user interface (GUI) such as 
Omnitron’s NetOutlook management software.
The  intuitive  NetOutlook  network  management  software  
provides real-time detailed port and module information as well 
as parameter configuration and event monitoring.  NetOutlook   
can  be  used  as  a  stand-alone  application  under  Windows  
2000/2003/XP/Vista/Windows7 or integrated with third-party 
SNMP management software.
Static  parameters  that  can  be  monitored  on  the  5-Module 
Chassis include the chassis type and model, manufacturing 
information, along with hardware and software revisions and 
serial  numbers  of  the  power  supplies.    Dynamic  real-time 
parameters that can be monitored include voltage, current and 
temperature for the power supplies.
In  addition  to  all  standard  iConverter  SNMP  traps  such  as 
module insertion and removal, the power supply modules can 
generate traps for out of voltage or chassis temperature range.  
All of these events can selectively be enabled or disabled to 
cause SNMP traps.
Chassis Type
5-Module AC
5-Module AC*
High Airflow
5-Module 24VDC 5-Module 48VDC 5-Module 48VDC*
High Airflow
Model Number
8220-x
8221-2
8226-x
8225-x
8227-2
Module Capacity
5
Power Supply 
Capacity
1 or 2
2
1 or 2
1 or 2
2
Power 
Requirements 
(typical)
33 watts
100 to 240VAC
50/60Hz
0.5A @ 120VAC
10A @ 3.3VDC
66 watts
100 to 240VAC
50/60Hz
1.5A @ 120VAC
20A @ 3.3VDC
33 watts
+/- 18 to 36VDC
1.4A @ 24VDC
10A @ 3.3VDC
33 watts
+/- 36 to 60VDC
0.7A @ 48VDC
10A @ 3.3VDC
66 watts
+/- 36 to 60VDC
2.0A @ 48VDC
20A @ 3.3VDC
Dimensions
W: 17.15” x D: 9.0” x H: 1.75”
Weight
7.5 lbs (822x-1)
9.0 lbs (822x-2)
Compliances
UL, CE, FCC Class A
Temperature
Standard:
Wide:
Storage:
         0 to 50° C
      -40 to 60° C
      -40 to 80° C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
43,000 (1 PS)
173,000 (2 PS)
90,000 (2 PS)
49,700 (1 PS)
198,000 (2 PS)
49,700 (1 PS)
198,000 (2 PS)
90,000 (2PS)
Configuration
5-Module Chassis
AC
(33 watts)
AC
High 
Airflow
(66 watts)
24VDC
(33 watts)
48VDC
(33 watts)
48VDC
High 
Airflow
(66 watts)
One (1) Power Supply
8220-1
-
8226-1
8225-1
-
Two (2) Power Supplies
8220-2
8221-2
8226-2
8225-2
8227-2
Spare Power Supply
8220-9
8221-9
8226-9
8225-9
8227-9`
23” Rack Mount Kit
8092-2
Blank Module Panel
8090-0
For wide temperature (-40 to 60° C) add a “W” to the end of the model number.  
Consult factory for extended temperature (-40 to 75° C) models.
* Agency compliances are pending.  Required for 
iConverter
 XG+ models.  Register at Omnitron-Systems.com to download the 
iConverter
 XG+ Usage Guide.