Viewsonic CDE3203 Manual De Usuario

Descargar
Página de 53
29
3. Protocol
3.1 Set-Function Listing
The PC can control the TV/DS for specific actions. The Set-Function command 
allows you to control the TV/DS behavior in a remote site through the RS232 port. 
The Set-Function packet format consists of 9 bytes.
Set-Function description:
Length:
Total Byte of Message excluding “CR”
TV/DS ID:
Identification for each of TV/DS (01~98; default is 01)
ID “99” means to apply the set command for all connected displays. 
Under such circumstances, only ID#1 display has to reply.
The TV/DS ID can be set via the OSD menu for each TV/DS set. 
Command Type: Identify command type,
“s” (0x73h) : Set Command
“+” (0x2Bh) : Valid command Reply
“-” (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code
Value[1~3]:
Three bytes ASCII that defines the value
CR:
0x0D
Set-Function format:
Send: (Command Type= “s”)
Name 
Length
ID
Command Type Command Value1 Value2 Value3 
CR
Byte Count 1 Byte 2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
6
7
8
9
Reply: (Command Type= “+” or “-”)
Name 
Length
ID
Command Type
CR
Byte Count 1 Byte 2 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
[NOTE] 
1.  The reply for “Power on” command is the exception for VT2405LED-1 and 
VT3205LED. It’s 0x322B0D ( 2+<CR>).
2.  When PC applies command to all displays (ID=99), only the #1 set needs to reply 
by the name of ID=1.
Example1: Set Brightness as 76 for TV-02 and this command is valid
Send (Hex Format)
Name 
Length
ID
Command Type Command Value1 Value2 Value3 
CR
Hex
0x38
0x30
0x32
0x73
0x24
0x30
0x37
0x36
0x0D