Sony MVC-CD400 Manual

Descargar
Página de 132
 model name1[MVC-CD400/CD250]
 [3-075-356-12(1)]
98
filename[C:\MVC-CD400Nouhinn\3075356121\307535612MVCCD400U2\13trb.fm]
masterpage:Left
Troubleshooting
If you experience trouble with your camera, 
try the following solutions.
1
First check the items on the tables below. 
If code displays “C:
ss
:
ss
” 
appear on the LCD screen, the 
self-diagnostics display function 
is working (page 108)
.
2
Should your camera still not work 
properly, press the RESET button on the 
bottom of the camera, then turn on the 
power again. (All the settings including 
date and time are cleared.)
3
Should your camera still not work 
properly, consult your Sony dealer or 
local authorized Sony service facility.
Battery pack and power
RESET button
Symptom
Cause
Solution
You cannot charge the 
battery pack.
• The camera is turned on.
p Turn the camera off (page 17).
The battery remaining 
indicator is incorrect, or 
sufficient battery 
remaining indicator is 
displayed but the power 
runs out soon.
• You have used the camera for a long time in an 
extremely hot or an extremely cold location. 
• The battery pack is dead (page 121)
• The battery pack is discharged. 
• A deviation has occurred in the remaining 
battery time.
p Replace the battery pack with a new one. 
p Install a charged battery pack (page 13).
p Fully charge the battery pack (page 14).
The battery life is short.
• You are shooting/viewing images in an 
extremely cold location.
• The battery pack is not charged enough.
• The battery pack is dead (page 121).
p Fully charge the battery pack (page 13).
p Replace the battery pack with a new one.
The  /CHG lamp flashes 
when charging a battery 
pack.
• The battery pack has malfunctioned.
p Contact your Sony dealer or local authorized Sony service 
facility.
Troubleshooting