Bretford 54" Jumper Cable DPJ54 Manual De Usuario

Los códigos de productos
DPJ54
Descargar
Página de 3
COMPONENT DIMENSIONS
Power In Feed Cable with Sensor
  DPP120 - 120"l x 1
5/8
"d x 3"h
4-Outlet Power Strip
  DPCF4 - 17
3/4
"l x 1
5/8
"d x 2
1/2
"h
Jumper Cables
  DPJ12 - 12"l 
 
DPJ62 - 62”l
  DPJ32 - 32"l 
 
DPJ74 - 74”l
  DPJ38 - 38"l 
 
DPJ86 - 86”l
  DPJ42 - 42"l 
 
DPJ102 - 102”l
  DPJ54 - 54"l 
 
DPJ118 - 118”l
  DPJ58 - 58"l
CARTON DIMENSIONS & UPC CODES
Power In Feed Cable with Sensor
  DPP120 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33344 8
4-Outlet Power Strip
  DPCF4 - 20”l x 4
1/2
”d x 4”h 
0 96633 33835 1
Jumper Cables
  DPJ12 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33836 8
  DPJ32 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33988 4
  DPJ38 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33837 5
  DPJ42 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33838 2
  DPJ54 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33839 9
  DPJ58 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33989 1
  DPJ62 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33840 5
  DPJ74 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33345 5
  DPJ86 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33841 2
  DPJ102 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33890 7
  DPJ118 - 10
1/4
”l x 6
1/2
”d x 4
1/2
”h 
0 96633 33991 4
POWER STRIP SEQUENCING
The key system on Fluid is all keyed alike and tables (power 
strips) may be arranged and rearranged in any order.
HOW TO ORDER
1.  Order one DPCF4 Power Strip for each table, carrel or power 
  door on a conference table.
2. Order one DPP120 Power In-Feed cable for each first power 
  strip in the row. (Row of four tables max or four power strips 
  max for each conference table or large library table/carrel.)
3. Order the appropriate Jumper Cable to connect the 2nd, 3rd, 
  and 4th power strips.
UL RECOGNIZED
The Fluid Power System has been tested by Underwriter 
Laboratories for safety and UL Recognized to standard UL962 
for commercial furnishing components. Fluid is intended 
for  mounting power units to specific Bretford tables and not         
intended for use in other applications. Fluid has not been       
approved by the ESA for use in Ontario Canada.
ELECTRICAL SPECIFICATIONS
The Fluid Power System has a 12-amp total system rating and 
powers off a single circuit 15-amp electrical outlet. Supports 
up to four 4-outlet DPCF4 power strips, 16-outlets total, from 
one outlet. Additional 15-amp circuits are required when more 
than four DPCF4 power strips are used. When an excess of four 
power strips or 12-amps are placed on the system, the power 
in-feed sensor shuts down and the LED indicator light will 
change from green to a solid red color. Once the excess outlets 
or power strips are unplugged from the system the LED light 
will change back to green indicating the system has reset. Fluid 
uses common keying between components to allows power 
units to attach in any sequence.
WARRANTY
Bretford warranties the Fluid Power System for 1-year, at date of 
shipment, against defects from materials or workmanship.
MADE IN THE USA
Components of the Fluid Power System are manufactured for 
Bretford in the USA.
Power In-Feed
Power Strip
Jumper Cable
Power In-Feed
Power Strip
Jumper Cable
Table 1
Table 2
Table 3
Table 4