ASUS ASMB8-iKVM Guía Del Usuario
3-4
Chapter 3: ASUS Host Management Controller Set-up
To view the System Event Log (SEL):
1. Select
BMC SEL
from the View command option, then press <Enter>. A complete
list of system event records appear on the left pane. The right pane displays the SEL
information.
The number on the left bottom of the window shows the system event displayed in the
right window pane over the total number of system events in the remote host.
2.
Use the down arrow key to display the next sensor event.
3.
Press <Esc> to return to the main screen.
ASUS Host Management Controller Setup Menu
: Select Menu ESC: Exit Up/Down
KCS
Initial
View
Set Monitor Help
Systen Event Log: (Hex)
01 00 02 09 4E 98 45 20
00 04 02 3A 01 50 19 09
1/202
1/202
Record ID :
0001h
Record Type :
02h (System Event Record)
Date & Date :
Fri Jan 21 20:43:00 2011
General ID :
2008h
EvM Rev :
04h (IPMI 1.5)
Sensor Type :
02h (Voltage)
Sensor Number:
3Ah (+1.1V_IOH)
Event Dir :
01h (Threshold)
Event Datal :
50h
Event Value :
19h (0.2 V)
Threshold :
09h 1.0 V)
Offset:
Lower Non-critical - going low