  Chapter 2.  VLANs
 
   
|
     
13
ProSafe 7000 Managed Switch Release 8.0.3 
a. Select Switching > VLAN > Advanced > Port PVID Configuration. A screen similar 
to the following displays.
b.  Under PVID Configuration, scroll down and select the check box for Interface 1/0/1
Then scroll down and select the Interface 1/0/2 check box.
c.  Enter the following information:
•     
In the Acceptable Frame Type polyhedron list, select VLAN Only.
•     
In the PVID (1 to 4093) field, enter 2.
d.  Click Apply to save the settings.
Assign Ports to VLAN3
This example shows how to assign the ports that will belong to VLAN 3, and to specify that 
untagged frames will be accepted on port 1/0/4. Note that port 1/0/2 belongs to both VLANs 
and that port 1/0/1 can never belong to VLAN 3.
CLI: Assign Ports to VLAN3
(Netgear Switch) (Config)#interface range 1/0/2-1/0/4
(Netgear Switch) (conf-if-range-1/0/2-1/0/4)#vlan participation include 3
(Netgear Switch) (conf-if-range-1/0/2-1/0/4)#exit
(Netgear Switch) (Config)#interface 1/0/4
(Netgear Switch) (Interface 1/0/4)#vlan acceptframe all
(Netgear Switch) (Interface 1/0/4)#exit
(Netgear Switch) (Config)#exit