322
   
|    
Chapter 19.  SNMP 
 
ProSafe 7000 Managed Switch Release 8.0.3 
Web Interface: Add a New Community
1. 
Select System > SNMP > SNMP V1/V2 > Community Configuration. A screen similar 
to the following displays.
2. 
In the Community Name field, enter public@4.
3. 
In the Client Address field, enter 0.0.0.0.
4. 
In the Client IP Mask field, enter 0.0.0.0.
5. 
In the Access Mode field, select Read/Write.
6. 
In the Status field, select Enable
7. 
Click Add.
Enable SNMP Trap
The example is shown as CLI commands and as a Web interface procedure.
CLI: Enable SNMP Trap
This example shows how to send SNMP trap to the SNMP server.
(Netgear switch) #config
(Netgear switch) (Config)# snmptrap public 10.100.5.17 
                                       Enable send trap to SNMP server 10.100.5.17 
(Netgear switch) (Config)#snmp-server traps linkmode
                                       Enable send link status to the SNMP server when 