Netgear GSM7228PS - ProSAFE 28 ports Gigabit Ethernet L2 Managed Stackable Switch with PoE Guía De Administador
322
|
Chapter 19. SNMP
ProSafe 7000 Managed Switch Release 8.0.3
Web Interface: Add a New Community
1.
Select System > SNMP > SNMP V1/V2 > Community Configuration. A screen similar
to the following displays.
to the following displays.
2.
In the Community Name field, enter public@4.
3.
In the Client Address field, enter 0.0.0.0.
4.
In the Client IP Mask field, enter 0.0.0.0.
5.
In the Access Mode field, select Read/Write.
6.
In the Status field, select Enable.
7.
Click Add.
Enable SNMP Trap
The example is shown as CLI commands and as a Web interface procedure.
CLI: Enable SNMP Trap
This example shows how to send SNMP trap to the SNMP server.
(Netgear switch) #config
(Netgear switch) (Config)# snmptrap public 10.100.5.17
Enable send trap to SNMP server 10.100.5.17
(Netgear switch) (Config)#snmp-server traps linkmode
Enable send link status to the SNMP server when