Netgear GSM7228PS - ProSAFE 28 ports Gigabit Ethernet L2 Managed Stackable Switch with PoE Manual De Hardware

Descargar
Página de 39
  Chapter 2:  Hardware Installation    
|
    
25
Managed Stackable Switches GSM7200PS and GSM7300S Series Hardware Installation Guide
Power Module Bay
The power module bay provides an easy way to replace a failed power module APS525W or 
APS135W. If the switch needs to continue to operate while you replace the power supply, an 
appropriate Redundant Power Supply (RPS) must be used to connect to the redundant 
power supply connector on the switch rear panel.
Installing a Power Module
To install a power module, follow these steps:
WARNING!
When inserting a power module into the switch, do not use 
unnessary force. Doing so can damage the connectors on the rear 
of the supply and on the midplane
1. 
Insert the new power supply module into the power module slot, and gently push the 
module into the slot.
Figure 2-18  Insert the Power Supply Module
2. 
Align the two captive screws with the screw holes in the switch’s rear panel.
3. 
Using a screwdriver, gently tighten the captive screws.
4. 
Connect the power cord to the module and to an AC-powered outlet.
Removing a Power Module
To remove a power module, follow these steps:
1. 
Disconnect the power cord from the power module.
2. 
Remove the power cord from the power connector.
3. 
Loosen the two captive screws on the power module.
4. 
Remove the power module from the power module slot by pulling on the extraction handle.