Netgear M4100-D12G (GSM5212v1h1) - 10‐port GE + 2 GE Combo L2 Managed PD Switch Manual De Usuario

Descargar
Página de 446
Configure System Information 
80
M4100 Series Managed Switch 
The following table describes the PoE Configuration nonconfigurable fields.
Table 23.  Advanced PoE Configuration
Field
Description
Units
Displays the Current PoE Unit. You can change the PoE Unit by 
selecting another unit ID listed here. 
Firmware Version 
Version of the PoE controller's FW image. 
Power Status 
Indicates the power status. 
Total Power (Main AC)
Displays the total power provided by the MAIN AC power source.
Total Power (RPS)
Displays the total power provided by the redundant power source.
Power Source
Current source of system power (Main AC or RPS).
Threshold Power 
System can power up one port, if consumed power is less than this 
power. That is, consumed power can be between Nominal and 
Threshold Power values. The threshold power value is effected by 
changing System Usage Threshold. 
Consumed Power 
Total amount of a power that is currently being delivered to all ports. 
Configure a PoE Port
To configure a PoE port:
1. 
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for 
example, 169.254.100.201.
2. 
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on 
the switch.
3. 
Launch a web browser.
4. 
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100. 
The Login screen displays.
5. 
Enter the user name and password. 
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
6. 
Click the Login button. 
The web management interface menu displays.