Netgear M4100-12GF (GSM7212F) - ProSAFE Gigabit L2+ Managed Switch Guía De Administador

Descargar
Página de 353
VLANs 
16
ProSAFE M4100 Managed Switches 
A screen similar to the following displays.
b.  Enter the following information:
In the VLAN ID field, enter 3.
In the VLAN Name field, enter VLAN3.
In the VLAN Type list, select Static.
c.  Click Add.
Assign Ports to VLAN2
This sequence shows how to assign ports to VLAN2, and to specify that frames will always 
be transmitted tagged from all member ports and that untagged frames will be rejected on 
receipt.
CLI: Assign Ports to VLAN2
(Netgear Switch) #config
(Netgear Switch) (Config)#interface range 1/0/1-1/0/2
(Netgear Switch) (conf-if-range-1/0/1-1/0/2)#vlan participation include 2
(Netgear Switch) (conf-if-range-1/0/1-1/0/2)#vlan acceptframe vlanonly
(Netgear Switch) (conf-if-range-1/0/1-1/0/2)#vlan pvid 2
(Netgear Switch) (conf-if-range-1/0/1-1/0/2)#exit
(Netgear Switch) (Config)#vlan port tagging all 2
(Netgear Switch) (Config)#
Web Interface: Assign Ports to VLAN2
1. 
Assign ports to VLAN2.
a. Select Switching > VLAN > Advanced > VLAN Membership