Netgear M4100-12GF (GSM7212F) - ProSAFE Gigabit L2+ Managed Switch Guía De Administador

Descargar
Página de 353
Security Management 
235
 ProSAFE M4100 Managed Switches
After a port is in an authorized state, if any client initiates dot1x authentication, the port 
clears authenticated clients’ states, and in the process clears the VLAN assigned to the 
port (if any). Then the port continues with the new client authentication and authorization 
process. 
When a client authenticates itself initially on the network, the switch acts as the 
authenticator to the clients on the network and forwards the authentication request to the 
RADIUS server in the network. 
For use in VLAN assignment, the following tunnel attributes are used:
Tunnel-Type = VLAN (13)
Tunnel-Medium-Type = 802
Tunnel-Private-Group-ID = VLANID where VLANID is 12 bits, with a value between 1 and 
4094.
192.168.0.1
RADIUS
server
192.168.0.3
Host
1/0/6
1/0/5
1/0/5
192.168.0.5
Switch
vlan2000
Host 1/0/12
Figure 24. VLAN assignment using RADIUS
In the previous figure, the switch has placed the host in the VLAN (vlan2000) based on the 
user details of the clients. 
The configuration on a RADIUS server for a user logged in as admin is:
Tunnel-Type = VLAN (13)
Tunnel-Medium-Type = 802
Tunnel-Private-Group-ID = 2000
CLI: Assign VLANS Using RADIUS
1. 
(Netgear Switch) #network protocol none 
Changing protocol mode will reset ip configuration.
Are you sure you want to continue? (y/n) y
(Netgear Switch) #network parms 192.168.0.5 255.255.255.0
(Netgear Switch) #vlan database
(Netgear Switch) (Vlan)#vlan 2000
(Netgear Switch) #exit
Create VLAN 2000.