KitchenAid 4.1 cu. ft. True Convection Upper Oven Guía De Instalación

Descargar
Página de 5
Page 1
4 screws (double oven)
Phillips
screwdriver
Product dimensions
Cutout dimensions
Before you start...
49-1/2"
recessed
height
51" max.
overall
height
28-3/8" max. 
recessed width
23" max.
recessed
depth
Double oven
Single oven
27-1/2"
recessed
height
28-3/8" max.
recessed
width
23" max.
recessed
29" max.
overall
height
30" min.
cabinet
1" top of cutout
to bottom of
upper cabinet
door
30" min.
cabinet width
30" min.
cabinet width
28-1/2"
cutout
width
28-1/2"
cutout
width
49-3/4"
min.
cutout
height
14-3/4"
bottom
of cutout
to floor
1-1/2" min.
bottom of
cutout to top of
cabinet door
28-1/2"
cutout width
5-1/4" bottom of
cutout to floor
27-3/4"
min.
cutout
height
1-1/2" min.
top of cutout
to underside
of countertop
1" top of cutout
to bottom of
upper cabinet
door
1-1/2"
min.
bottom of
cutout to
top of
cabinet
door
32"
bottom of
cutout to
floor
Single oven
undercounter
(without cooktop 
installed above)
Double oven
Cabinet side view
Single oven
27-3/4"
min.
cutout
height
23-1/4" min.
cutout depth
23" recessed
oven depth
recessed 
oven
cabinet
oven
front
Important: Observe all governing codes 
and ordinances.
Proper installation is your responsibility. 
Have a qualified technician install this oven. 
Oven location should be away from strong draft
areas, such as windows, doors and strong
heating vents.
Cabinet opening dimensions that are shown
must be used. Given dimensions provide
minimum clearance. 
Recessed installation area must provide
complete enclosure around the recessed portion
of the oven.
Electrical ground is required. See “Electrical
requirements.”
Electrical supply junction box should be located
3 inches maximum below the support surface
when oven is installed in a wall cabinet. Drill a 
1-inch minimum diameter hole in the right rear
or left rear corner of the support surface to pass
the appliance cable through to the junction box.
For undercounter installation, it is recommended
that the junction box be located in the adjacent
right or left cabinet. If installing the junction box
on rear wall behind oven, junction box must be
recessed 
and located in the upper or lower right
or left corner of cabinet.
Oven support surface MUST be solid, level and
flush with bottom of cabinet cutout.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Tool needed:
Parts supplied:
Cabinet filler kits are available from your dealer.
Use a matching color kit if oven is smaller than your
cabinet opening.
Single oven filler height is 3-5/16"
Black
— 4378941
White — 
4378942
Almond — 4378943
Double oven filler height is 6-5/16"
Black — 
4378947
White — 
4378948
Almond — 4378949
29-3/4"
overall width
29-3/4"
overall width
It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 — latest edition*,
and all local codes and ordinances.
Your safety and the safety of others are 
very important.
We have provided many important safety
messages in this manual and on your appliance.
Always read and obey all safety messages.
This is the safety alert symbol. 
This symbol alerts you to potential hazards
that can kill or hurt you and others. 
All safety messages will follow the safety alert
symbol and either the word “DANGER” or
“WARNING”. These words mean:
All safety messages will tell you what the potential
hazard is, tell you how to reduce the chance of
injury, and tell you what can happen if the
instructions are not followed.
You can be killed or seriously injured if you
don’t immediately follow instructions.
You can be killed or seriously injured if you
don’t follow instructions.
WARNING