Network Connectivity 
48 
WorkCentre 5845/5855/5865/5875/5890 Multifunction Printer 
 
System Administrator Guide 
Raw TCP/IP Printing 
Raw TCP/IP is used to open a TCP socket-level connection over Port 9100, and stream a print-ready file 
to the printer input buffer. It then closes the connection either after sensing an End Of Job character in 
the PDL or after expiration of a preset timeout value. Port 9100 does not require an LPR request from the 
computer or the use of an LPD running on the printer. Raw TCP/IP printing is selected in Windows as the 
Standard TCP/IP port. 
 
Configuring Raw TCP/IP Settings 
1.  In CentreWare Internet Services, click 
Properties > Connectivity > Setup
2.  Under Protocol, next to Raw TCP/IP Printing, click 
Edit
3.  Under Protocol, select 
Enabled
4.  Next to TCP Port Number, ensure that Port 1 is set to 
9100
To emulate HP JetDirect EX Plus 3, set Port 2 to 
9101 and Port 3 to 9102
5.  Next to Bidirectional, for each active port, select 
Enabled
6.  Next to Maximum Connections per Port, for each active port, type a number from 1 through 32. 
7.  Next to End of Job Timeout, for each active port, type a time in seconds from 0 through 1800. 
8.  Next to PDL Switching, for each active port, select 
Enabled as needed. PDL Switching allows the 
printer to switch automatically between multiple supported PDLs within a single job. 
9.  Click 
Apply to save the new settings or Undo to retain the previous settings. 
 
Configuring Raw TCP/IP Advanced Settings 
1.  On the Raw TCP/IP Printing page, click the 
Advanced tab. 
2.  Under Connections, set the following: 
−  Set the Maximum Connections per port between 
1–32. The default port value is 32. 
−  To allow concurrent jobs to process for each port connection, type a number between 
0–500 
jobs in each port. Type 
0 to allow unlimited concurrent jobs.   
−  To limit the number of jobs that are active for each port connection, type a number between 
0–32768. Type 0 to allow unlimited number of active jobs. 
3.  Under Job Boundary Determination: 
−  Type the End of Job Timeout between 
0–1800 seconds to specify the amount of time to pass 
before a job processes with an End of Job character. The default time is 300 seconds. Type 
0 
to disable end of job detection by timeout. 
4.  Under Backchannel Data: 
−  Enable 
Backchannel Data Transmission to Client, then, enable Out of Order Backchannel 
Data to allow data from several jobs to be interspersed. 
 
Note: 
Out of Order Backchannel Data is only available when Backchannel Data Transmission to 
Client is enabled.