ELECTRICAL
High Voltage Wiring
Requirements
•  Humidifier MUST be connected GFCI circuit.
•  15 amp, 120/240 volt circuit required.
•  Local disconnect must be installed for future servicing.
•  Wiring must be performed by a licensed electrician.
High Voltage Wiring Install Process
Hard wire the unit to local circuit disconnect as shown below.
1
2
3
4
5
M36307
1
2
3
4
5
M36308
1
2
3
4
5
M36309
1
2
3
4
5
M36310
1
2
3
4
5
M36311
M36312
M36313
1.  Connect ground to the peg at right.
120 Volt:  use the yellow jumper wire (supplied) 
to connect 
terminals 1 & 2.
4.  Insert jumper wire: 
120 Volt:  use the yellow jumper wire (supplied) 
to connect 
terminals 1 & 4.
3.  Connect hot to terminal 5.
2.  Connect neutral to terminal 1 (or hot, in 
the case of 240 volt).
5.  Remove the ground wire screw from the case body.
6.  Clip the other end of the green ground wire as close as possible to the drain 
valve. Remove the cut wire.