10. TROUBLESHOOTING
Table 6
7. Bear in mind to check serviceability of the relief valve every 14 days   
inspection method:
- turn the discharge lever to the left up until you feel the change of thread, 
then water must start flowing from the valve's hole. After checking the 
water flow, return the lever to its initial position.
IMPORTANT!
If water doesn't flow, then the valve is damaged. In this case you 
must not use the heater and it is recommended to call for a service 
technician.
8. If necessary, wipe external surfaces of the heater by a damp cloth with 
soap.
Possible malfunctions and troubleshooting methods
11. WIRING DIAGRAM
Fig.19
Switch   only for RS series
Indicator light   only for MS2/RS7 series
Switch
Temperature limiter
Thermostat
Heating 
indicator 
light
Heater
6. To drain water from the internal tank properly, you need to use the 
drain  hole  (only  for  RS2/MS2  line)  (it  is  necessary  to  unscrew  a  plug, 
covering the drain hole), water can also be drained through a composite 
relief valve (Fig. 14) (unscrew the composite relief valve drain knob screw 
and set the drain knob to the upper position, at that hot water tap must 
be open, and cold water supply valve must be closed).
IMPORTANT!
If these actions had no positive result or the thermal switch turns 
off repeatedly during a short period of time, then you should de-
energize the water heater, cut off water supply and contact your 
local Timberk Authorized Service Center for a consult or repair of 
the appliance.
IMPORTANT!
Never drain water if its temperature is over 50°C since it may result in 
burns.
1. Temperature adjustment device is broken.
2. Temperature limiter was actuated or was 
not switched on.
3. Temperature limiter is broken.
1. Water feed is cut off.
2. Water pressure is too low.
3. Water supply exhaust valve is closed.
Water temperature control system is 
damaged.
Seal at the point of pipe connection is 
broken.
Breaking of the internal tank (corrosion)Seal 
at the point of the heating element 
connection is broken.
1. Temperature adjustment device is broken.
2. Insufficient time for heating.
3. Heating element is broken.
Contact a repairer, TIMBERK service center.
Switch on the temperature switch following 
instructions on its activation. (page 15)
Contact a repairer, TIMBERK service center.
1. Wait until water supply is restored.
2. Switch on the water heater again, when 
normal water pressure restores.
Contact a repairer, TIMBERK service center.
Replace the joint seal.
Contact a repairer, TIMBERK service center.
1. Contact a repairer, TIMBERK service center.
2. Wait until water is heated.
3. Contact a repairer, TIMBERK service center.
Heating indicator light 
doesn't light up, water is 
not heated
Water doesn't flow from the 
hot water discharge cock
Water temperature is too 
high
Water leakage
Water flows from the 
appliance's case
Heating indicator light 
lights up but water is not 
heated
FAILURE
POSSIBLE CAUSES