Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP) Notas de publicación

Descargar
Página de 18
 
15
Release Notes for Cisco ONS 15454 SDH Release 7.0.1
78-xxxxx-xx
  New Features and Functionality
CSCei37691
The trunk port service state for the TXPP and TXP cards does not transition to unlocked-disabled,failed 
in the presence of an LOS-P alarm. This can occur when the payload signal for LOS-P is missing for the 
particular port type. This issue is resolved in Release 7.0.
CSCuk57046
An unexpected Mismatch Equipment Attributes (MEA) transient alarm can occur on rapidly inserting 
and removing a PPM. This issue can occur with a TXP_MR_10E-L for which you preprovision an 
OC-192 PPM. The transient alarm is raised on the PPM. This issue is resolved in Release 7.0.
Electrical IO Cards
CSCsd59042
When upgrading the software from Release 6.x.x to Release 7.x.x, the DS3 and E3 cards fail to load if 
the node name begins with the letters FL. Changing the node name resolves this issue.
TL1
CSCsc62784
The Calibration Tilt is not properly changed using the TL1 interface. The reference tilt is changed 
instead. This issue can be seen when you try to change the CALTILT parameter on amplifier cards using 
the ED-OTS command. To avoid this issue, use CTC. This issue is resolved in Release 7.0.1.
New Features and Functionality
This section highlights new features and functionality for Release 7.0.1. For detailed documentation of 
each of these features, consult the user documentation.
New Software Features and Functionality
Secure Mode on Multishelf
In Release 7.0.1 both single-shelf and multishelf configurations support the use of secure mode and 
locked secure mode. The procedures for using secure mode in multishelf configurations do not differ 
from the procedures used in single shelf configurations. The default setting for secure mode is “off.” 
Consult the user documentation prior to using secure mode in any configuration.