The ONS 15454 is environmentally hardened and will function at  operating temperatures of -40 
to 149 degrees Fahrenheit (-40 to +65 degrees Celsius) and humidity of 5 to 95 percent (non-
condensing) when configured with the following components: 
 
   15454-SA-ANSI 
Shelf 
    15454-FTA2 Fan Tray 
    15454-FTA3-T Fan Tray 
   15454-TCC+T 
   15454-TCC2 
   15454-XC-T 
   15454-XC-VT-T 
   15454-AIC-T 
   15454-AIC-I 
   15454-AEP 
   15454-DS1-14 
   15454-DS1N-14 
   15454-DS3-12-T 
   15454-DS3-12E-T 
   15454-DS3N-12E-T 
   15454-DS3XM-6-T 
   15454-EC1-12-T 
   15454-OC34IR1310-T 
   15454-OC38IR1310-T 
   15454-OC12IIR1310-T 
   15454-OC12ILR1310-T 
   15454-OC12ILR1550-T 
 
For all other configurations, the ONS 15454 functions at operating temperatures of 32 to 131 
degrees Fahrenheit (0 to +55 degrees Celsius). 
 
When installed in an ONS 15454, all plug-in cards meet the following safety requirements: 
 
   UL 
1950 
    CSA C22.2 No. 950 
   EN 
60950 
   IEC 
60950 
 
Power Specifications 
 
    Recommended Input Voltage: -48VDC 
o
  Two –48VDC power feeds (Breaker A and Breaker B) 
    Acceptable Input Voltage Range: -42 to –57VDC 
    Maximum Power Consumption: 1060W (System Release 3.1 or higher); 952W (System 
Release prior to 3.1) 
    Recommended Amperage: 30A (System Release 3.1 or higher); 20A (System Release 
prior to 3.1) 
    Power Terminals: #6 Lug 
 
Bandwidth Capacity 
 
    Total Capacity: 240 Gb/s 
    Data Plane Bandwidth: 160 Gb/s 
    SONET plane bandwidth: 80 Gb/s