The ONS 15454 is environmentally hardened and will function at operating temperatures of -40
to 149 degrees Fahrenheit (-40 to +65 degrees Celsius) and humidity of 5 to 95 percent (non-
condensing) when configured with the following components:
to 149 degrees Fahrenheit (-40 to +65 degrees Celsius) and humidity of 5 to 95 percent (non-
condensing) when configured with the following components:
15454-SA-ANSI
Shelf
15454-FTA2 Fan Tray
15454-FTA3-T Fan Tray
15454-TCC+T
15454-TCC2
15454-XC-T
15454-XC-VT-T
15454-AIC-T
15454-AIC-I
15454-AEP
15454-DS1-14
15454-DS1N-14
15454-DS3-12-T
15454-DS3-12E-T
15454-DS3N-12E-T
15454-DS3XM-6-T
15454-EC1-12-T
15454-OC34IR1310-T
15454-OC38IR1310-T
15454-OC12IIR1310-T
15454-OC12ILR1310-T
15454-OC12ILR1550-T
For all other configurations, the ONS 15454 functions at operating temperatures of 32 to 131
degrees Fahrenheit (0 to +55 degrees Celsius).
When installed in an ONS 15454, all plug-in cards meet the following safety requirements:
UL
1950
CSA C22.2 No. 950
EN
60950
IEC
60950
Power Specifications
Recommended Input Voltage: -48VDC
o
Two –48VDC power feeds (Breaker A and Breaker B)
Acceptable Input Voltage Range: -42 to –57VDC
Maximum Power Consumption: 1060W (System Release 3.1 or higher); 952W (System
Release prior to 3.1)
Recommended Amperage: 30A (System Release 3.1 or higher); 20A (System Release
prior to 3.1)
Power Terminals: #6 Lug
Bandwidth Capacity
Total Capacity: 240 Gb/s
Data Plane Bandwidth: 160 Gb/s
SONET plane bandwidth: 80 Gb/s