Cisco Cisco ONS 15454 SONET Multiservice Provisioning Platform (MSPP) Guía De Diseño
OL-4556-01
196
AIC and AIC-I Card Specifications
Table 6-16 lists the physical characteristics and environmental specifications for the AIC and AIC-
I cards.
Table 6-16: AIC and AIC-I Card Specifications
Specification AIC
AIC-I
Alarm inputs
4 without AEP
– Opto coupler isolated
– Label customer provisionable
– Severity customer provisionable
– Common 32 V output for all alarm
– Opto coupler isolated
– Label customer provisionable
– Severity customer provisionable
– Common 32 V output for all alarm
inputs
– Each input limited to 2 mA
– Termination: Wire-wrap on
– Termination: Wire-wrap on
backplane without AEP, on AEP
connectors with AEP
connectors with AEP
12 without AEP, 32 with AEP
– Opto coupler isolated
– Label customer provisionable
– Severity customer provisionable
– Common 32 V output for all alarm
– Opto coupler isolated
– Label customer provisionable
– Severity customer provisionable
– Common 32 V output for all alarm
inputs
– Each input limited to 2 mA
– Termination: Wire-wrap on
– Termination: Wire-wrap on
backplane without AEP, on AEP
connectors with AEP
connectors with AEP
Alarm outputs
4 (user configurable as inputs)
– Switched by opto MOS (metal oxide
– Switched by opto MOS (metal oxide
semiconductor)
– Triggered by definable alarm
condition
– Maximum allowed open circuit
voltage: 60 VDC
– Maximum allowed closed circuit
current: 100 mA
– Termination: Wire-wrap on
backplane without AEP, on AEP
connectors with AEP
connectors with AEP
4 (user configurable as inputs) without
AEP, 16 with AEP
– Switched by opto MOS (metal oxide
AEP, 16 with AEP
– Switched by opto MOS (metal oxide
semiconductor)
– Triggered by definable alarm
condition
– Maximum allowed open circuit
voltage: 60 VDC
– Maximum allowed closed circuit
current: 100 mA
– Termination: Wire-wrap on
backplane without AEP, on AEP
connectors with AEP
connectors with AEP
Orderwire
Extended and Local Orderwire
supported
supported
Extended and Local Orderwire
supported
supported
UDC
– Bit rate: 64 kb/s, co-directional
– ITU-T G.703
– Input/output impedance: 120 ohm
– Termination: RJ-11 connectors
– ITU-T G.703
– Input/output impedance: 120 ohm
– Termination: RJ-11 connectors
– Bit rate: 64 kb/s, co-directional
– ITU-T G.703
– Input/output impedance: 120 ohm
– Termination: RJ-11 connectors
– ITU-T G.703
– Input/output impedance: 120 ohm
– Termination: RJ-11 connectors
DCC/GCC
– Bit rate: 576 kb/s
– EIA/TIA-485/V11
– Input/output impedance: 120 ohm
– Termination: RJ-45 connectors
– EIA/TIA-485/V11
– Input/output impedance: 120 ohm
– Termination: RJ-45 connectors
– Bit rate: 576 kb/s
– EIA/TIA-485/V11
– Input/output impedance: 120 ohm
– Termination: RJ-45 connectors
– EIA/TIA-485/V11
– Input/output impedance: 120 ohm
– Termination: RJ-45 connectors
Optional AEP
No
Yes
Power Monitoring Alarming States
NA
– Power failure (0 to –38 VDC)
– Undervoltage (–38 to–40.5 VDC)
– Overvoltage (beyond –56.7 VDC)
– Undervoltage (–38 to–40.5 VDC)
– Overvoltage (beyond –56.7 VDC)
Environmental:
Operating Temperature
- C-Temp (15454-AIC): 32 to 131
degrees Fahrenheit (0 to +55
degrees Celsius)
degrees Celsius)
- I-Temp (15454-AIC-I-T):–40 to 149
degrees Fahrenheit (–40 to +65
degrees Celsius)
degrees Celsius)
–40 to 149 degrees Fahrenheit (–40 to
+65 degrees Celsius)
+65 degrees Celsius)
Operating Humidity
5 to 95%, noncondensing
5 to 95%, noncondensing
Power Consumption (including AEP,
if used)
6.01 W, 0.12 A, 20.52 BTU/hr
8.00 W, 0.17 A, 27.3 BTU/hr
Physical Characteristics:
Height
12.650 in. (321.3 mm)
12.650 in. (321.3 mm)
Width
0.716 in. (18.2 mm)
0.716 in. (18.2 mm)
Depth
9.000 in. (228.6 mm)
9.000 in. (228.6 mm)
Weight
1.8 lb (0.82 kg)
1.8 lb (0.82 kg)
Compliance
UL 1950, CSA C22.2 No. 950, EN
60950, IEC 60950, ISO 9001
60950, IEC 60950, ISO 9001
UL 1950, CSA C22.2 No. 950, EN
60950, IEC 60950, ISO 9001
60950, IEC 60950, ISO 9001
Predicted MTBF (Years)
1
42 22
1
Markov modeling was used to calculate the predicted MTBF.