Figure 3-4: DS3/Au3 Aggregation Application
SDH
Handoffs
To
Subm arine
DWDM
STM-64
DS3/Au3
SDH
Aggregation
Subm arine
Landing Site
Customer Site
STM-16/64
Leased
SONET/Data
Services
Trans-Oce anic
Carrier
ONS 15454
SDH
Handoffs
To
Subm arine
DWDM
STM-64
DS3/Au3
SDH
Aggregation
Subm arine
Landing Site
Customer Site
STM-16/64
Leased
SONET/Data
Services
Trans-Oce anic
Carrier
ONS 15454
SDH Hairpinning
Some rules must be followed when an ONS 15454 is used in an SDH “hairpinning” application.
SDH hairpinning applies when a cross-connected circuit is set-up between SDH configured
optical cards on the same ONS 15454 node. Table 3-3 shows the optical cards that can be used
to hairpin circuits between two SDH configured optical ports on the same ONS 15454 node.
Table 3-3: SDH Hairpinning Compatibility Table
Optical Cards
STM-1
STM-4
STM-16
HS
STM-16
AS
STM-64
OC-3/STM-1
OK
OK OK OK OK
OC-12/STM-4 OK OK OK
Not
Supported
Not
Supported
OC-48/STM-16
High-Speed slot
versions
High-Speed slot
versions
OK OK OK
Not
Supported
Not
Supported
OC-48/STM-16
Any-slot versions
Any-slot versions
OK
Not
Supported
Not
Supported
OK OK
OC-192/STM-64 OK
Not
Supported
Not
Supported
OK OK
Managing Third-Party Network Equipment
You can use the DCC tunneling feature of the Cisco ONS 15454 to provide the ability to
transparently interconnect third party management channels of the connected SDH networks (see
Figure 3-5).