CSCea68773
The ACTV/STBY LED shows AMBER when a 2.5G transponder is first connected. The DWDM cards 
introduced a new design: When all the ports are OOS on a card, the card is considered to be in standby 
mode. 
Interoperability
CSCsl22337
When a DWDM ring or network has to be managed through a Telcordia operations support system 
(OSS), every node in the network must be set up as multi-shelf. OLA sites and nodes with one shelf must 
be set up as "multi-shelf stand-alone" to avoid the use of LAN switches.
Resolved Caveats for Release 7.0.1
This section documents caveats resolved in Release 7.0 and 7.0.1. 
Maintenance and Administration
CSCsd55460
When upgrading a network to Release 6.0.1, 6.1, or 7.0, where LOS-P exists on a pass-through port of 
a WSS for a ROADM node, if you change the circuit state to OOS,DSBLD and then again to IS-AINS, 
the circuit fails to go up. There are two possible work-arounds: 
1.
Change the calibration value on the pass-through port of the WSS.
2.
When the circuit is in OOS state, relaunch ANS.
This issue is resolved in Releases 6.2 and 7.0.1.
CSCsd31753
After card pre-provisioning, if you launch an ANS default patchcord using CTC or TL1, the TCC resets 
and internal patchcords are not created. This can occur in an OADM or Flexible terminal MSTP node 
configured with any possible combination of AD-xC card, but containing wavelength 1560.61 (that is 
AD-1C-60.6, AD-2C-59.7 and AD-4C-58.1). Any Fiber stage configuration will display this issue. This 
issue is resolved in Release 7.0.1.
CSCsc61572
Traffic incurs a hit when a Y-cable protection group is created with an IS working facility and 
OOS,DSBLD protect facility. If a Y-cable protection group is created, and traffic is flowing cleanly over 
the working facility, and the protect facility is OOS,DSBLD, the working facility will momentarily 