Cisco Cisco MDS 9000 NX-OS Software Release 5.2 Notas de publicación

Descargar
Página de 66
21
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(6)
OL-27554-01
  Downgrading Your Cisco MDS SAN-OS Software Image
Downgrading Guidelines Specific to NX-OS Release 5.2(6)
The following guidelines applies to a downgrade from Cisco MDS NX-OS Release 5.2(6):
Cisco NX-OS Release 5.2(6) supports IDLE as a fill word for the switchport fill-pattern command. 
Releases earlier than  Release 5.2(6) supported only the ARBFF fill word. As a result, when you 
downgrade from Cisco NX-OS Release 5.2(6) to an earlier release that does not support the IDLE 
fill word, the following syntax error occurs:
Syntax error while parsing 'switchport fill-pattern IDLE speed 8000'
The syntax error message is harmless and can be ignored.
You cannot nondisruptively downgrade from NX-OS Release 5.2(6) to NX-OS Release 5.0(x) if you 
installed NX-OS Release 5.2(6) on an MDS 9509 or MDS 9506 switch and you installed a 
Generation 4 module in the switch and performed a full switch reload. The reason for this restriction 
is the change in fabric mode that occurs following the switch reload with the Generation 4 hardware 
installed. The downgrade will be disruptive, even if you remove the Generation 4 module prior to 
starting the downgrade.
If you do not install Generation 4 hardware or perform a full switch reload following the installation 
of NX-OS Release 5.2(6) on an MDS 9509 or MDS 9506 switch, then you can nondisruptively 
downgrade to NX-OS Release 5.0(x).
If you have the Storage Media Encryption (SME) application configured on your system, you must 
delete signature clusters when downgrading from Cisco NX-OS Release 5.2(6) to Release 5.2(1). 
Following a ISSD from Cisco NX-OS Release 5.2(6) to an earlier Release 5.2(x) or to Release 5.0(x) 
on a Cisco MDS 9000 switch that is configured with IVR or FCR, reload the modules with the ELS 
trap entry. In the case of FCR, reload the module with the FCR device logged in. For IVR, all 
modules should be reloaded.
We recommend that you delete any SPAN configuration, Fibre Channel tunnel, or tunnel-ID map 
configuration from your switch before you downgrade from NX-OS Release 5.2(6) to a lower 
version. If any SPAN session, SPAN destination, SPAN target, or Fibre Channel tunnel interface is 
configured, the installer should detect it and prompt you to delete these configurations. 
To gather information about SPAN sessions and delete them, use the following commands in this 
order:
show incompatibility systems bootflash:image_name to display any incompatible 
configurations
show span session to check the current configuration for a SPAN session
no span session session-number to delete a SPAN session
show running-config | include fc-tunnel to check the current Fibre Channel tunnel 
configuration
no interface fc-tunney to delete a Fibre Channel tunnel on the switch that is the source for the 
Fibre Channel tunnel
show interface brief | include SD to check the current configuration for a SPAN destination 
port configuration
show interface brief | include ST to check the current configuration for a SPAN target port 
configuration
no fc-tunnel tunnel-map z interface x/y to remove an Fibre Channel tunnel map
no switchport mode sd to negate the SPAN destination port mode for the SPAN destination port