CSCuu76450
Symptom: MDS fabric switch running in NPV mode fails to generate port-monitor alerts.
Conditions: Applies to all MDS fabric switches running in NPV mode using port-monitor.
Applies to all versions prior to NX-OS 6.2(13).
Will occur only in the following conditions:
- After one or more upstream NP or TNP ports goes down and then back up. 
- For each (T)NP port that flaps, one F port at the end of the range of ports
will no longer be scanned for port-monitor counter events. For example, if the
(T)NP port fc1/1 flaps then the last F port being used(ex. fc1/48) will no 
longer be scanned for port-monitor counter events.
Related Documentation
The documentation set for NX-OS for the Cisco MDS 9000 Family includes the following documents. 
To find a document online, access the following web site:
The documentation set for Cisco Fabric Manager appears in the Cisco Fabric Manager Release Notes 
for Release 4.2(1)
, which is available from the following website:
Release Notes 
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Releases 
Cisco MDS 9000 Family Release Notes for MDS SAN-OS Releases
Cisco MDS 9000 Family Release Notes for Storage Services Interface Images 
Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images
Regulatory Compliance and Safety Information 
Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family 
Compatibility Information 
Cisco Data Center Interoperability Support Matrix
Cisco MDS 9000 NX-OS Hardware and Software Compatibility Information and Feature Lists
Cisco MDS NX-OS Release Compatibility Matrix for Storage Service Interface Images 
Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide