  Caveats
Caveats
Review the notes listed below before deploying the ONS 15454. Caveats with tracking numbers are 
known system limitations that are scheduled to be addressed in a subsequent release. Caveats without 
tracking numbers are provided to point out procedural or situational considerations when deploying the 
product.
Alarms
CSCsj26750
When the card type in CTC is changed from DS1_14 to DS1_E1_56 with DS1-14 physical card in the 
slot, the LED in DS1_14 card will show Act (Green) LED, instead of Fail (RED) LED. This issue will 
be resolved in a future release.
Hardware
CSCsj43651
Occasional hits appear in DS3XM12 traffic during 1:N PG manual switch happens. This issue also 
occurs when switch happens due to hard reset and or soft reset conditions.
This issue occurs under the following conditions:
DS3 Payload with DS3 Framing-M13 
DS1 Pay load with Framing-ESF.
Workaround is to either change the DS1 Payload Framing to D4 or keep it unframed.
This issue will be resolved in a future release.
CSCsj43438
Cards do not come up after hard rest and or soft reset when TCC2 is stressed.
This issue will be resolved in a future release.
CSCsj41576
Traffic on DS3E card is interrupted for more than two seconds.
CONTBUS-IO_A or CONTBUS-IO_A alarms appear along with an AutoReset of DS3E card.
This issue occurs when TCC is fully loaded with different scripts running on it. Also, no Protection 
Group is available for DS3E card. The DS3E traffic interruption happens because the DS3E goes for a 
watchdog reset due to timing out of socket communication attempts with TCC. Since TCC is unable to 
service the socket requests from DS3E, the IO card times out after three minutes since the start of socket 
open attempt, and goes for a watchdog reset.
Workaround: