Release Notes for Cisco ONS 15454 Release 6.2.1
OL-10164-01
  New Features and Functionality
configuration. If you avoid using the manual switch command on the active protect card when the 
working card is in WTR, you will not see this issue. This issue is resolved in Releases 6.0.1, 6.1, 6.2, 
and 7.0. 
CSCsc34405
Injecting a single CRC error on a DS1-56 card when framing mode is set to ESF can result in multiple 
CRCs being reported. This issue is resolved in Release 6.1.
Alarms
CSCsc80841
The alarm daemon fails to scale in large networks. Alarm Summary/TID SNMP traps exhaust the DCC 
buffers causing packet drop in large networks. There is no workaround for this; however, a workaround 
for the issue of the DCC buffer becoming exhausted is to divide the network into multiple OSPF areas. 
This issue is resolved in Release 6.2.
TL1
CSCsb69372
Nodes that are discovered through a TL1 tunnel might become permanently grayed out when the tunnel 
far end NE reboots. This condition can occur when one or more TL1 tunnels are active and a tunnel far 
end NE reboots. To recover from this condition, restart CTC. This issue is resolved in Release 6.1.
CSCsb82157
You cannot set the Gain (EXPGAIN) value using the TL1 ED-OTS command when the node is 
configured as Metro Access. Use CTC to set the gain in this case. This issue is resolved in Releases 6.1 
and 7.0, and in maintenance Release 6.0.1.
New Features and Functionality
This section highlights new features and functionality for Release 6.2. For detailed documentation of 
each of these features, consult the user documentation.
New Software Features and Functionality
Release 6.2 adds the following new software features.