Release Notes for Cisco ONS 15454 SDH Release 6.2.2
OL-10929-01
  Resolved Caveats for Release 6.2.x
Bridge and Roll
CSCei37364
When a rollTo leg is not receiving a good signal, and because of this the rollPending alarm is not cleared, 
there is no alarm indicating the reason that the RollPending alarm fails to clear. This issue is resolved in 
Release 7.0.
Resolved Caveats for Release 6.2.x
This section highlights resolved caveats for Release 6.2.x. 
Hardware
CSCsb77209
Split route circuits on some FC_MR-4 cards will take some errors at -5C to +10C ambient temperatures. 
This issue is resolved in Releases 6.0.1, 6.1, and 7.0. 
Maintenance and Administration
CSCsd67191
Rarely, in a large network with many host routes the Proxy ARP server might run out of ring buffer 
storage, resulting in a subsequent failure of the driver to receive new packets. This can lead to DCC 
failure and loss of all connections. This issue is resolved in Releases 6.2 and 8.
CSCsd55460
When upgrading a network to Release 6.0.1, 6.1, or 7.0, where LOS-P exists on a pass-through port of 
a WSS for a ROADM node, if you change the circuit state to OOS,DSBLD and then again to IS-AINS, 
the circuit fails to go up. There are two possible workarounds: 
1.
Change the calibration value on the pass-through port of the WSS.
2.
When the circuit is in OOS state, relaunch ANS.
This issue is resolved in Releases 6.2 and 7.0.1.
CSCei88893
The 6.312 MHz BITS Output signal does not lock properly to its incoming reference. This issue is 
resolved in Release 6.2.