Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP) Notas de publicación

Descargar
Página de 73
 
30
Release Notes for Cisco ONS 15454 SDH Release 7.0.5
OL-13084-01
  Resolved Caveats for Release 7.0.x
Resolved Caveats for Release 7.0.x
This section highlights resolved caveats for Release 7.0.x. 
Maintenance and Administration
CSCsg17018
The Inhibit FE loopback parameter for the mentioned cards should be set to true. (The check box should 
be checked.) Before you test this, a) Please delete the database. (FlmDeleteDb) b) And reboot the node. 
(Reboot)
You can check the parameter as mentioned below. 
Card View  
Maintenance Pane 
Loopback Pane
Port pane on the card for which this is supported. (Mentioned in the bracket) 
For 7.04 310MA
DS1_28_DS3_EC1_3_LINE_CARD (DS3 Port)
DS1_84_DS3_EC1_3_LINE_CARD (DS3 Port)
15454 
DS3XM_LINE_CARD (DS3)
DS3XM12_LINE_CARD (DS3)
DS3I_LINE_CARD (DS3I)
DS3E_LINE_CARD (DS3)
DS3_EC1_48_LINE_CARD (DS3 & EC1 Port)
DS1_E1_56_LINE_CARD (You can see these values on loopback pane itself)
CSCsg25085
Have Ds3Xm12 card and move DS3 to IS.
Step 1
Create Vt circuit in IS state
Step 2
See Ds1 ports used in circuits have state in IS.
Step 3
Change circuit state to OOS, MT by editing the circuit from circuit edit pane.
Step 4
Ds1 ports state used for circuits will be OOS,MT
Step 5
Now apply loopback
Step 6
Release loopback and confirm that Ds1 port state will move to VT circuit state if Ds3 is IS, in this case 
Ds1 port state will be OOS, MT.