Cisco Cisco ONS 15310-MA SONET Multiservice Platform Referencia técnica

Descargar
Página de 23
5
Note
Port number 3082 is a raw TCP/IP port; it is not an interactive port and is not recommended 
for use as an alternate telnet port.
Step 1
At the DOS prompt, type cmd and press Enter. (The same steps can also be done from a Unix 
prompt).
Step 2
At the DOS command prompt type: 
TELNET <NODE IP ADDRESS OR NODE NAME> <PORT NUMBER> and press Enter.
The Node IP address or Node Name refers to the IP address or Node Name of the node you 
want to communicate with. Port number is the port (2361 or 3083) where TL1 commands are 
understood. If the connection is successful, a screen opens with a prompt.
Step 3
You are ready to log into TL1. Follow the steps in the 
.
Use a Craft Interface to Open a TL1 Session
ONS 15454, ONS 15310-CL, and ONS 15310-MA
The TCC2/TCC2P, XTC, 15310-CL-CTX, and CTX2500 cards have two built-in interface ports for 
accessing the ONS 15454, ONS 15310-CL, and ONS 15310-MA respectively. With one RJ-45 LAN 
connection you can access the system using a standard browser interface. In the browser interface, you 
can perform local and remote Operations, Administration, Maintenance, and Provisioning (OAM&P) 
functions and open a VT100 emulation window to enter TL1 commands. If a browser is not available, 
you can access the system using a nine-pin RS-232 port. The RS-232 port supports VT100 emulation 
such that TL1 commands may be entered directly without a browser. The ONS 15310-MA has two 
RJ-45 serial craft ports.
Step 1
Connect the serial cable to the RS-232 port on the active TCC2/TCC2P, to serial craft port of 
XTC, 15310-CL-CTX, or CTX2500 card.
Step 2
Configure the terminal emulation software (Hyperterminal):
a.
Terminal emulation = vt100
b.
Bits per second = 9600
c.
Parity = None
d.
Stop BITS = 1
e.
Flow control = None
Step 3
Press Enter. An angle bracket prompt (>) appears.