Cisco Cisco Video Surveillance 2500 IP Camera Hoja De Datos
Data Sheet
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 4 of 6
Software
Table 4 describes the primary features of the Cisco Video Surveillance 2500 Series IP Camera software.
Table 4.
Cisco Video Surveillance 2500 Series IP Camera Primary Software Features
Item
Specification
Activity Detection
4 user-definable motion detection areas, e-mail alert, and FTP uploading of captured video or JPEG snapshots
triggered by motion alert
triggered by motion alert
Wireless Security
Wired Equivalent Privacy (WEP) 64/128, Temporal Key Integrity Protocol (TKIP), Wi-Fi Protected Access Preshared
Key (WPA-PSK), WPA2
Key (WPA-PSK), WPA2
Video Format
NTSC and PAL
Day/night Settings
Auto or manual day/night operation with user-definable thresholds
Image Settings
Configurable brightness, sharpness, contrast, saturation, and white balance
Overlay Capabilities
Time, date, and text
Selectable Bit Rate
Support for Constant Bit Rate or Variable Bit Rate* (constant quality)
IP Filtering*
Users can enter a list of allowed or blocked IP addresses for viewing video and configuring camera settings
Discovery*
Cisco Discovery Protocol, Bonjour Zero-Configuration discovery
Configuration
●
Browser-based using Internet Explorer 6.x with SP2 and later
●
Multiple user access levels with password protection
* Not supported when the camera is used with Cisco Video Surveillance Manager.
Specifications
Table 5 provides specifications of the Cisco Video Surveillance 2500 Series IP Camera.
Table 5.
Cisco Video Surveillance 2500 Series IP Camera Specifications
Item
Specification
Housing
Aluminum
LEDs
Power, Ethernet link, and activity
Dimensions (L x W x H)
●
4.8 x 3.1 x 2 in.
●
122 x 80 x 50 mm
Weight
●
1.15 lb
●
0.52 kg
Certifications
Safety:
IEC 60950-1:2001
EN 60950-2:2001 +A11:2004
EMC-Emissions:
FCC Part 12 Subpart B, Class B
CISPR 22 Class B
ICES-003, Class B
ANSI C63.4
EN 55022: Class B
EN 61000-3-2
EN61000-3-3
EMC-Immunity:
EN 55024
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Operating Temperature
●
32 to 122°F
●
0 to 50°C