Resolved Caveats for Release 4.1.2
Resolved Caveats for Release 4.1.2
The following items are resolved in Release 4.1.2
Line Cards
DDTS # CSCeb34326
Rarely, an E1-42 card can go into continual autoreset. This can occur after the E1-42 card is inserted, or 
following a node power cycle. Hard reset the E1-42 by removing and re-inserting it into the chassis to 
stop this cycle. This issue is resolved in a Release 4.1.2.
DDTS # CSCec13638
Rarely, a greater than 2 second traffic hit can occur when the active XC is pulled, then you switch the IO 
from active (Working) to standby (protect). This issue is resolved in Release 4.1.2.
DDTS # CSCeb42187
Occasionally, if you remove the active working E1-42 card, the card takes a greater than 60 ms hit. This 
issue is resolved in Release 4.1.2. 
DDTS # CSCeb41057
On an E1-42, the LOSS-L parameter appears as random values. For example, sometimes it appears as 
-269,488,145. This makes the count unavailable from the card. This issue is resolved in Releases 4.6 and 
4.1.2.
DDTS # CSCeb49051
If you configure 1:N or 1:1 protection for DS1, DS3, E1, or E3, then lock the XC and soft reset the active 
XC, after the XC finishes resetting, the protection for the electrical cards switches. This issue is resolved 
in Releases 4.1.2 and 4.6.
ML Series
DDTS # CSCin25238
If you configure Fast EtherChannel and POS-channel in the same bridge group, during system boot, the 
Fast EtherChannel or POS-channel configuration may be lost and following error message displayed:
Interface FastEthernet1 is attempting to join Port-channel1. But Port-channel1 
belongs to bridge-group 1 which has another FE(C) member in it. FEC + FE(C) is not 
allowed in the same bridge group. Please change your configuration and retry.