Cisco Cisco ONS 15454 SONET Multiservice Provisioning Platform (MSPP) Notas de publicación
3
Release Notes for Cisco ONS 15454 Release 4.1.2
OL-4983-01
Changes to the Release Notes
Changes to the Release Notes
This section documents supplemental changes that have been added to the Release Notes for Cisco ONS
15454 Release 4.1.2 since the production of the Cisco ONS 15454 System Software CD for Release
4.1.2.
15454 Release 4.1.2 since the production of the Cisco ONS 15454 System Software CD for Release
4.1.2.
There are no changes to the release notes for Release 4.1.2.
Caveats
Review the notes listed below before deploying the ONS 15454. Caveats with DDTS tracking numbers
are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without
DDTS tracking numbers are provided to point out procedural or situational considerations when
deploying the product.
are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without
DDTS tracking numbers are provided to point out procedural or situational considerations when
deploying the product.
Hardware
CWDM and DWDM GBIC Compatibility with G1000-4 Cards and G1K-4 Cards
Existing G1000-4 cards are expected to support CWDM and DWDM GBICs, but final qualification
testing was not complete at press time. The online version of the 4.1.x user documentation and release
notes will be updated to reflect the final qualification status of CWDM and DWDM GBICs on the
G1000-4 card, when this information is available.
testing was not complete at press time. The online version of the 4.1.x user documentation and release
notes will be updated to reflect the final qualification status of CWDM and DWDM GBICs on the
G1000-4 card, when this information is available.
Existing G1K-4 cards do not support CWDM or DWDM GBICs.
G1K-4 cards with the CLEI code of WM5IRWPCAA (manufactured after August 2003) are expected to
support CWDM and DWDM GBICs, but final qualification testing was not complete at press time. The
online version of the 4.1.x user documentation and release notes will be updated to reflect the final
qualification status of CWDM and DWDM GBICs on the G1K-4 card with the CLEI code of
WM5IRWPCAA, when this information is available.
support CWDM and DWDM GBICs, but final qualification testing was not complete at press time. The
online version of the 4.1.x user documentation and release notes will be updated to reflect the final
qualification status of CWDM and DWDM GBICs on the G1K-4 card with the CLEI code of
WM5IRWPCAA, when this information is available.
Note
Operating temperature of the DWDM GBICs is -5 degrees C to 40 degrees C.
DDTS # CSCdy48478 Fan Tray Assembly Fan Fail Lamp Test Failure
A user-initiated lamp test does not illuminate the fan fail LED on the fan tray assembly for the ONS
15454 or the ONS 15454 SDH. The lamp test successfully lights the LEDs for major, minor, and critical
alarms on the fan tray, and for all cards in the chassis, but does not light the fan fail LED. An actual fan
failure, however, will light the fan fail LED.
15454 or the ONS 15454 SDH. The lamp test successfully lights the LEDs for major, minor, and critical
alarms on the fan tray, and for all cards in the chassis, but does not light the fan fail LED. An actual fan
failure, however, will light the fan fail LED.