Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP) Notas de publicación
6
Release Notes for Cisco ONS 15454 SDH Release 8.5.4
OL-20571-01
Resolved Caveats for Release 8.5.4
CSCsv45464—The RTRV-OCHNC command with AID=ALL does not return any information about the
existing cross connections
existing cross connections
The RTRV-OCHNC command with the access identifier (AID) =ALL does not return any information
about the existing cross connections. The workaround is to provide the RTRV-OCHNC command with
AID=LINEWL-x-all, where x is the slot number in which the 40-WXC card is provisioned. This issue
will be resolved in a future release.
about the existing cross connections. The workaround is to provide the RTRV-OCHNC command with
AID=LINEWL-x-all, where x is the slot number in which the 40-WXC card is provisioned. This issue
will be resolved in a future release.
CSCsv71398—The RTRV-MOD command displays LBC and OPT parameters with invalid values
The RTRV-MOD command displays LBC and OPT parameters with invalid values for pluggables that
do not support these values. The workaround is to use CTC. This issue will be resolved in a future
release.
do not support these values. The workaround is to use CTC. This issue will be resolved in a future
release.
CSCsw92329—TL1 do not initialize PM counts on all ports of MRC card
The INIT-REG-<Mod> TL1 command does not initialize the PM counts when trying to initialize a
specific PM count on all ports on the MRC-12 card, except for the first port. This issue will be resolved
in a future release.
specific PM count on all ports on the MRC-12 card, except for the first port. This issue will be resolved
in a future release.
CSCsz81750—Traffic loss for 50 ms on MXPP-MR-2.5G and TXPP-MR-2.5G cards
Traffic loss for 50 ms on MXPP-MR-2.5G and TXPP-MR-2.5G cards under the following conditions:
1.
Splitter protection with protect active.
2.
Manual reset of the card causes traffic loss.
This issue will be resolved in a future release.
CSCta30336—Internal communication error reported for a preprovisioned card
Internal communication error is reported when the INIT-REG-VC11 TL1 command is issued on the
proprovisioned STM16 card. This issue will be resolved in a future release.
proprovisioned STM16 card. This issue will be resolved in a future release.
Resolved Caveats for Release 8.5.4
This section documents caveats resolved in Release 8.5.4.
Alarms
CSCsy69110—ADD Port Alarm not Raised
Add Port alarm is not raised on ports 27 and 23 of 40-WSS card when the 40-WSS card is inserted in
Slot 3 of an ONS 15454 SDH shelf. This issue has been resolved.
Slot 3 of an ONS 15454 SDH shelf. This issue has been resolved.