Installing ONS 15454 SDH OC3 IR 4/STM1 SH 1310 Cards
78-14608-01
Removal Procedures
Removal Procedures
Use this section if you are installing or removing the OC3 IR 4/STM1 SH 1310 card for the first time. 
After you become familiar with ONS 15454 SDH card installation and boot up, use this section as a 
reference. 
Caution
Always use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15454 
SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf 
assembly and ensure the shelf assembly is properly grounded.
Caution
Hazardous voltage or energy may be present on the backplane when the system is operating. Use caution 
when servicing. 
Note
Traffic can be interrupted if you pull an active card from the ONS 15454 SDH. Use caution when 
replacing cards and verify that only inactive or standby cards are being replaced. If an active card needs 
to be replaced, follow the procedure to switch the electrical card to standby mode before you pull the 
card from the node.
Reset an STM-N Card
Note
An STM-N reset can cause a linear 1+1 STM-N protection switch or an MSSPRing protection switch. 
Note
Traffic can be interrupted if you pull an active card from the ONS 15454 SDH. Use caution when 
replacing cards and verify that only inactive or standby cards are being replaced. If an active card needs 
to be replaced, follow the procedure to switch the STM-N card to standby mode before you pull the card 
from the node.
Warning
Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products.
Warning
Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do 
not stare into the beam or view directly with optical instruments. Viewing the laser output with 
certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance 
of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other 
than those specified may result in hazardous radiation exposure.
The STM-N card should be replaced if a red FAIL LED appears.
Take these precautions before initiating an STM-N card reset to avoid causing a linear 1+1 or MSSPRing 
protection switch:
Step 1
Ensure that the working (active) span is active on the local and remote nodes.