Cisco Cisco Unified MeetingPlace Audio Server Manual De Mantenimiento

Descargar
Página de 348
7-22  Solving problems 
Cisco MeetingPlace Audio Server System Manager’s Guide
February 27, 2004
Interpreting LEDs on the 8106 server
The MeetingPlace 8106 server has three types of LEDs, as described in the 
following table.
Major Alarm
Appears red when a serious problem exists with 
your MeetingPlace system. This kind of condition 
usually interrupts system operation.
Critical Alarm
Disregard. Currently not in use.
Hot Swap Controller (HSC) 
power light
Appears green when there is power to the card, 
which also means that there is power to the system.
Component
LED Color
Meaning
Fan assembly
• none
• red
• Fan assembly is working properly or is not properly 
inserted
• Fan assembly is not working properly
Power supply 
units
• green on both
• red on both
• none on both
• green on one; red 
on other
• green on one; none 
on other
• red on one; none on 
other
• Power supply units are working properly
• Neither power supply unit is working properly. Shut off 
the server as soon as possible and remove all cards, the 
floppy drive and CD-ROM drive housing unit, and the 
disk drives
• Either the server is powered off or the power supply 
units are not properly inserted
• One power supply unit is working properly and the 
other is either bad or not properly inserted
• One power supply unit is working properly and the 
other is either bad or not properly inserted
• One power supply unit is bad and the other is not 
properly inserted
Disk drives
• green
• none
• Server is accessing the disk drive
• Server is not accessing the disk drive
Alarm light (8112)
Description