  Resolved Caveats for Release 5.0.6
Resolved Caveats for Release 5.0.6
The following caveats were resolved in Release 5.0.x.
Hardware
DDTS # CSCeh07574
Do not install an ASAP card in a system running Release 5.0. During normal testing at 50 deg C 
temperature the ASAP card can experience a silent failure that at times can be service affecting. Traffic 
might take errors when you run a fully loaded node with ASAP cards at 50 deg C temperature. Bit errors 
can occur on some ports. This issue is resolved in Release 5.0.2.
Maintenance and Administration
DDTS # CSCeg60310
Issuing ampersand ranging to manage a full line card's worth of STSs, while at the same time issuing 
CTC commands against STSs on the same line card, might cause the TSC to reset. This issue is resolved 
in Release 5.0.2.
DDTS # CSCea78286
In a network topology where ONS 15600 A and ONS 15600 B are connected to the same LAN, with 
OSPF turned on, both Nodes A and B in the same non-backbone area, and a virtual link created from 
Node A to a backbone router, if another virtual link to the backbone is created on Node B, a TSC switch 
may occur. To avoid this situation, do not design a network in the aforementioned configuration; 
specifically, do not create the second virtual link. This issue is resolved in Release 5.0.
DDTS # CSCdy43268
When the OSPF DCC Metric or the OSPF LAN Metric is modified via CTC, there is no change to the 
routing of traffic. If a link is broken anywhere in the network, or if the TSC is soft reset the traffic will 
then be routed appropriately. This issue is resolved in Release 5.0.
DDTS # CSCea47483
If you initiate a roll from the circuits tab, then switch to the rolls subtab of the circuits tab, select the 
circuit and press the finish button multiple times (for example, if you accidentally double-click the finish 
button) to complete the roll, then multiple circuits will be displayed on the circuits tab, only one of which 
is complete (the rest are incomplete). When completing a roll from the rolls subtab of the circuits tab, 
only press the finish button a single time for each circuit that you wish to roll. This issue is resolved in 