Chapter 4    Troubleshooting 
 
 
 
Low or Degraded Forward RF Signal 
The forward RF signal can be measured at the amplifier module forward input and at 
the Main, Aux 1, and Aux 2 forward output test points. 
 
Low or Degraded Forward RF Signal Troubleshooting Table 
Before you begin troubleshooting for a low or degraded forward RF signal, verify 
that the amplifier is receiving the proper forward RF input signal from the upstream 
amplifier. 
Important: You cannot balance the amplifier without the proper forward RF input 
signal. 
Make sure you have configured the amplifier module according to the specifications 
in the design print, and that the amplifier has warmed up for approximately one 
hour. 
Make sure you are using the proper tilt reference when setting levels. An 870 MHz or 
1 GHz design balanced at 550 MHz requires a corrected tilt reference to compensate 
for the difference in carrier levels between 550 MHz and 870 MHz or 1 GHz. The tilt 
reference at 550 MHz is lower than the tilt reference at 870 MHz or 1 GHz. Refer to 
the tilt charts in Technical Information (on page 93) for more information. 
Important: If the amplifier cover was ever removed, make sure it was properly 
reinstalled. Improperly reinstalling the amplifier module cover may result in RF 
signal degradation. 
Possible cause 
Solution 
Low or degraded forward RF signal 
at the forward input test point. 
 
Verify that the amplifier is receiving the proper 
forward RF input signal from the upstream 
amplifier. 
Important: You cannot balance the amplifier 
without the proper forward RF input signal. 
 