show alarm
show alarm statistics ▀
Cisco ASR 5x00 Statistics and Counters Reference ▄
2743
show alarm statistics
Table 183.
show alarm statistics
Command Output Descriptions
Field
Description
Current Outstanding
Alarms
Alarms
Indicates the alarm conditions that are currently active:
Total: The total number of currently outstanding alarms.
Critical (CR): This alarm is triggered when events cause a degradation in service.
Major (MJ): This alarm is triggered on the following conditions:
A hardware failure was detected on a card that will cause it to be taken off-line.
One of the Power Filter Units has failed or was removed.
One or more of the fans on either the upper or lower fan tray have failed.
The upper or lower fan tray has been removed.
Minor (MN): This alarm is triggered when a high temperature is detected on a card causing the
fan tray to switch to high speed.
fan tray to switch to high speed.
Cumulative Totals
Indicates the number of alarms that have occurred since the system was last booted:
Total: The total number of currently outstanding alarms.
Critical (CR): This alarm is triggered when events cause a degradation in service.
Major (MJ): This alarm is triggered on the following conditions:
A hardware failure was detected on a card that will cause it to be taken off-line.
One of the Power Filter Units has failed or was removed.
One or more of the fans on either the upper or lower fan tray have failed.
The upper or lower fan tray has been removed.
Minor (MN): This alarm is triggered when a high temperature is detected on a card causing the
fan tray to switch to high speed.
fan tray to switch to high speed.