Cisco Cisco Packet Data Interworking Function (PDIF) Prospecto
show port
▀ show port transceiver (ASR 5500)
▄ Cisco ASR 5x00 Statistics and Counters Reference
3764
show port transceiver (ASR 5500)
Table 449.
show port transceiver
Command Output Descriptions (ASR 5500)
Field
Description
Port <slot/port>
Specifies the chassis slot and port number for the port.
SFP Transceiver info
Identifies the type of transceiver installed in the port.
SFP Vendor info
Vendor Name: Identifies the vendor’s name
Vendor IEEE ID: Displays the module vendor’s IEEE ID.
Vendor IEEE ID: Displays the module vendor’s IEEE ID.
SFP Vendor Rev. info
Displays the revision level for this vendor’s module.
SFP Parts info
P/N: Displays the vendor’s part number for this transceiver.
S/N: Displays the vendor’s serial number for this module.
Date: Displays the vendor’s manufacturing date for this module.
S/N: Displays the vendor’s serial number for this module.
Date: Displays the vendor’s manufacturing date for this module.
Nominal Bitrate
Displays the nominal bitrate for this module in megabits per second,
Length 50/125um
Core size = 50/125 microns
Length 62.5/125um
Core size = 62.5/125 microns
Wavelength
Displays the wavelength in nanometers (nm).
Diagnostic Monitor
Indicates whether diagnostic monitoring is supported (Yes/No).
Internally Calibrated
Indicates whether this module is internally calibrated (Yes/No).
Externally Calibrated
Indicates whether this module is externally calibrated (Yes/No).
SFF-8472 Compliance
Indicates whether this module complies with SFF-8472 – Diagnostic Monitoring Interface for Optical
Transceivers (Yes/No).
Transceivers (Yes/No).
Alarms
Low Alarm Threshold – trigger value for Low Alarm parameter
Low Warn Threshold – trigger value for Low Warning Alarm parameter
Actual Value – current actual parameter value
High Warn Threshold – trigger value for High Warning Alarm parameter
High Alarm Threshold – trigger value for High Alarm parameter
Low Warn Threshold – trigger value for Low Warning Alarm parameter
Actual Value – current actual parameter value
High Warn Threshold – trigger value for High Warning Alarm parameter
High Alarm Threshold – trigger value for High Alarm parameter
Alarm Threshold
Parameters
Parameters
Temp (C) – temperature (Centigrade)
Voltage (V) – DC voltage
Bias (mA) – laser bias current in milliamperes
TxPower (dBm) – transmit power in decibels
RxPower (dBm) – receive power in decibels
Voltage (V) – DC voltage
Bias (mA) – laser bias current in milliamperes
TxPower (dBm) – transmit power in decibels
RxPower (dBm) – receive power in decibels