9
Updating Your Appliances
one at a time. This allows the other VAPs in the group to inspect network traffic 
while the VAP that is being updated reloads. If you are using single-VAP VAP 
groups in an inline deployment, reloading the VAP causes an interruption in 
network traffic. Make sure you plan the update for a maintenance window or 
other time when it will have the least impact on your deployment.
After the Installation
After you perform the update on either the Defense Center or managed devices, 
you must reapply device configuration and access control policies. Applying an 
access control policy may cause a short pause in traffic flow and processing, and 
may also cause a few packets to pass uninspected. For more information, see the 
Sourcefire 3D System User Guide.
There are several additional post-update steps you should take to ensure that 
your deployment is performing properly. These include:
verifying that the update succeeded
making sure that all appliances in your deployment are communicating 
successfully
updating your intrusion rules, if necessary
updating your vulnerability database (VDB) to at least version 220
making any required configuration changes based on the information in 
The next sections include detailed instructions not only on performing the update, 
but also on completing any post-update steps. Make sure you complete all of the 
listed tasks.
Updating a Defense Center
Use the procedure in this section to update your Defense Centers, including 
virtual Defense Centers. For the Version 5.3.0.3 update, Defense Centers reboot.
WARNING!
Before you update the Defense Center, reapply access control 
policies to any managed devices. Otherwise, the eventual update of the managed 
device may fail.
WARNING!
Do not reboot or shut down your appliances during the update until 
after you see the login prompt. The system may appear inactive during the 
pre-checks portion of the update; this is expected behavior and does not require 
you to reboot or shut down your appliances.